Welcome Customer !

Membership

Help

Anhui Guangzi Electric Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Article

Anhui Guangzi Electric Technology Co., Ltd

  • E-mail

    1151237588@qq.com

  • Phone

    13855073989

  • Address

    Renhe Road, Tianchang City, Anhui Province

Contact Now
Explosion proof grade of explosion-proof armored thermal resistance
Date: 2023-11-13Read: 4

Explosion proof platinum resistance products are suitable forWithin the temperature range of dIIBT4 to dIICT6, the explosion-proof thermistor uses imported components as temperature sensing elements, and its technical performance meets the technical requirements and division table of JB/T8622-1997 Industrial Platinum Electrical Technology. At the same time, the product meets the general requirements for explosion-proof electrical equipment used in explosive environments GB33836.1-2000 and GB3825.2-2000 standards. The National Instrument Explosion proof Supervision and Inspection Station conducts specialized review and approval of the product's drawings, technical documents, and prototypes, and issues an explosion-proof certificate of conformity.


Explosion-proof rating

The explosion-proof rating of explosion-proof thermal resistors is divided into three levels: A, B, and C, based on their suitability for explosive gas mixtures with the largest gap.

Temperature group

The temperature group of the explosion-proof thermistor is divided into six groups based on the highest surface temperature T1 to T6 of its exposed part.

Temperature group

Allow maximum surface temperature ℃

T1

T2

T3

T4

T5

T6

450

300

200

135

100

85

Model representation

Explosion proof thermistor

W

Z

P

Specifications

content

Temperature Instrument

thermal resistor

Thermal resistance material

-




2


Fixed thread

4


Fixed flange

6


Fixed thread conical protective tube

Installation fixed form

4


flameproof type

Form of junction box

S


Thermal resistance form

Thermal resistance form

A

Modification number

W

Z

P

-

S

A


Explosion proof armored thermistor

W

Z

P

K



Temperature Instrument

thermal resistor

Thermal resistance material

armor

-

2


Fixed thread


4


Fixed flange


4

flameproof type

Form of junction box


W

Z

P

K

-



Types and specifications of explosion-proof thermal resistors

category

model

graduation mark

Temperature measurement range ℃

protective tube material

Thermal response time T0.5S

Nominal pressure MPa

structural characteristics

Specifications

Explosion-proof rating

Total length L (mm)

Insertion depth 1 (mm)

platinum resistance thermometer

Wzp- 24 in

Pt100

-200~500

1cr18Ni9Ti

stainless steel

Or 0cr18Ni12MOTi

≤90

10

Explosion proof junction box: fixed thread installation M27


150

200

250

300

400

500

750

1000

dIIBT4

dIIBT6

or

dIICT4 dIICT6


WZP 2 - 24 to

Wzp- 44 in

6.4

Explosion proof junction box: fixed flange installation

WZP 2 - 44 to

WZP-64S

WZP2-64S

30

Cone shaped protective tube M33 * 2

100

200

300


Types and specifications of explosion-proof armored thermal resistors

category

model

graduation mark

Temperature measurement range ℃

protective tube material

Thermal response time T0.5S

Nominal pressure MPa

structural characteristics

Specifications

Explosion-proof rating

Total length L (mm)

Insertion depth 1 (mm)

platinum resistance thermometer

WZPK-24

Pt100

-200~500

Ø 6 or Ø 5

≤12

≤8

10

Explosion proof junction box: fixed thread installation M27 × 2


150

200

300

400

500

750

1000

dIIBT4

dIIBT6

or

dIICT4 dIICT6


WZPK2-24

WZPK-44

6.4


Explosion proof junction box: fixed flange installation

WZPK2-44

Note: The flange is a flat flange according to the instrument industry standard JB/T5219-1991


Install fixed position

The installation of fixed positions can be divided into three forms: fixed threads, tapered fixed threads, and fixed flanges. The structural dimensions are shown in the table.


Diameter of protective tube (d)

M

h

s

D0

Flow velocity m/s

Maximum operating pressure MPa

Straight protective tube fixing thread

F6

M27×2

32

32

F40


10

Conical protective tube fixing thread


M33×2

33

36

F48

80

30

Fixed flange

F16

D2

D1

D0

d

H

h


6.4

F95

F65

F45

F14

15

2