B division number intrinsic safety thermocouple compensation soft wire
Compensation wire for intrinsically safe thermocouple [B-type compensation cable]
IA-BC-GA-YVP polyethylene insulated polyvinyl chloride sheathed copper wire braided shielding precision grade B division number intrinsic safety thermocouple compensation wire
IA-BC-GA-YVRP polyethylene insulated polyvinyl chloride sheathed copper wire braided shielding precision grade B division number intrinsic safety thermocouple compensation flexible wire
IA-BC-HA-FFP Fluoroplastic Insulation and Sheath Copper Wire Braided Shielding Precision Grade B Division Number Intrinsic Safety Thermocouple Compensation Wire
IA-BC-HA-FFRP Fluoroplastic Insulation and Sheath Copper Wire Braided Shielding Precision Grade B Division Number Intrinsic Safety Thermocouple Compensation Flexible Wire
IA-BC-HA-FGP Fluoroplastic Insulation Silicone Rubber Sheath Copper Wire Braided Shielding Precision Grade B Division Number Intrinsic Safety Thermocouple Compensation Wire
IA-BC-HA-FGRP fluoroplastic insulation, silicone rubber sheath, copper wire braided shielding, precision grade B division number, intrinsic safety thermocouple compensation flexible wire
Note: The above models are only listed for KX, while others such as SC, KC, EX, NC, TX, JX only need to change the model * item,
Flame retardant type with ZR added before the model, ZR192 is made of imported PFA material,
Tin plated copper wire can be used for shielding.
B-type compensating cable
BC-GA-VVP PVC insulated and sheathed copper wire braided total shielding precision grade B division thermocouple compensation cable
BC-GA-VVRP PVC insulated and sheathed copper wire braided total shielding precision grade B division thermocouple compensating flexible cable
BC-GA-VPVP PVC insulated and sheathed copper wire braided split screen and total shielding precision grade B division thermocouple compensation cable
BC-GA-VPVRP PVC insulated and sheathed copper wire braided split screen and total shielding precision grade B division thermocouple compensating flexible cable
BC-GA-YJVP cross-linked polyethylene insulated polyvinyl chloride sheathed copper wire braided total shielding precision grade B division thermocouple compensation cable
BC-GA-YJVRP cross-linked polyethylene insulated polyvinyl chloride sheathed copper wire braided total shielding precision grade B division thermocouple compensating flexible cable
BC-GA-YJPVP cross-linked polyethylene insulated polyvinyl chloride sheathed copper wire braided split screen and total shielding precision grade B division thermocouple compensation cable
BC-GAYJPVRP cross-linked polyethylene insulated polyvinyl chloride sheathed copper wire braided split screen and total shielding precision grade B division number thermocouple compensating flexible cable
BC-HA-FFP fluoroplastic insulation and sheath copper wire braided total shielding precision grade B division thermocouple compensation cable
BC-HA-FFRP Fluoroplastic Insulation and Sheath Copper Wire Braided Total Shielding Precision Grade B Scale Thermocouple Compensation Flexible Cable
BC-HA-FPFP fluoroplastic insulated and sheathed copper wire braided split screen and total shielding precision grade B division thermocouple compensation cable
BC-HA-FPFRP fluoroplastic insulated and sheathed copper wire braided split screen and total shielding precision grade B division number compensating flexible cable for thermocouples
BC-HA-FVP fluoroplastic ene insulated polyvinyl chloride sheathed copper wire braided total shielding precision grade B division thermocouple compensation cable
BC-HA-FVRP fluoroplastic ene insulated polyvinyl chloride sheathed copper wire braided total shielding precision grade B division thermocouple compensating flexible cable
BC-HA-FPVP fluoroplastic insulated polyvinyl chloride sheathed copper wire braided split screen and total shielding precision grade B division thermocouple compensation cable
BC-HA-FPVRP fluoroplastic insulated polyvinyl chloride sheathed copper wire braided split screen and total shielding precision grade B division thermocouple compensating flexible cable
BC-HA-FGP fluoroplastic ene insulated silicone rubber sheathed copper wire braided total shielding precision grade B division thermocouple compensation cable
BC-HA-FGRP fluoroplastic ene insulated silicone rubber sheathed copper wire braided total shielding precision grade B division thermocouple compensating flexible cable
BC-HA-FPGP fluoroplastic insulated silicone rubber sheathed copper wire braided split screen and total shielding precision grade B division thermocouple compensation cable
BC-HA-FPGRP fluoroplastic insulated silicone rubber sheathed copper wire braided split screen and total shielding precision grade B division number thermocouple compensation flexible cable
Note: The above basic models only list copper wire or tin plated wire shielding methods. For other shielding types, simply change the shielding code, such as P copper wire braided shielding, P1 tin plated copper wire braided shielding, P2 copper tape wrapped shielding, P3 aluminum foil wrapped shielding
2 flame retardant type with ZR added before the model, 22 added after the steel tape armored cable model, and 32 ZR192 added after the steel wire armored cable model. It is an imported PFA material with a temperature resistance of 260 ℃
Product Overview
The function of compensating wires for thermocouples is to extend the thermoelectric electrode, which is the cold end of the moving thermocouple, and connect it with the display instrument to form a temperature measurement system. This product is equivalent to the national standard IEC 584-3 "Thermocouples Part 3- Compensation Wires". The insulation layer and protective layer are made of imported high-quality fluoroplastics, and a new process of integral continuous extrusion is adopted to make the product have excellent acid resistance, alkali resistance, wear resistance, and non flammability. It can be immersed in oil-water for long-term use. The operating temperature is between 60-205-260 ℃, which is at the advanced level of contemporary technology. The product is mainly used in various temperature measuring devices and has been widely used in sectors such as nuclear power, petroleum, chemical industry, metallurgy, and power.
Main technical indicators
Compensation wire models are classified according to product varieties as: SC, KC, KX, EX, JX, TX
Fill in: a) Model * letters correspond to the scale mark of the thermocouple;
b) The letter 'X' represents an extended compensating wire (type)
c) The letter 'C' represents compensation type compensation wire (type)
Note: SC type compensating wire daily equipped with R-type indexing thermocouple