Welcome Customer !

Membership

Help

Anhui Tiankang (Group) Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Article

Anhui Tiankang (Group) Co., Ltd

  • E-mail

    anhuitiankang@163.com

  • Phone

    13965985979

  • Address

    No. 20 Renhe South Road, Tianchang City, Chuzhou City, Anhui Province

Contact Now
Technical parameters of steel wire armored power cables
Date: 2018-07-20Read: 7

Technical parameters of steel wire armored power cables

Steel wire armored power cableproduct standard

This product is produced according to the GB12706 standard for extruded insulated power cables and accessories with rated voltage of 1kV~35kV. It can also be produced according to the recommended standards of IEC, British standards, German standards, and American standards according to user needs.
Scope of application of steel wire armored power cables
This product is suitable for fixed installation in power distribution networks or industrial installations with a rated voltage of 0.6/1kV and below.
Steel wire armored power cableUsage characteristics
The rated voltage Uo/U of the power frequency is 0.6/1kV.
The maximum allowable long-term working temperature for cable conductors is 90 ℃
Allowable maximum temperature for cable conductor during short circuit (maximum duration not exceeding 5 seconds): 250 ℃
The ambient temperature during cable laying should not be lower than 0 ℃.
The bending diameter of multi-core cables shall not be less than 15 times the outer diameter of the cable, and the bending diameter of single core cables shall not be less than 20 times the outer diameter of the cable.

Cable model, name and purpose

model

name

YJV
VLV

Copper core cross-linked polyethylene insulated polyvinyl chloride sheathed power cable

Aluminum core cross-linked polyethylene insulated polyvinyl chloride sheathed power cable

YJY
YJLY

Copper crosslinked polyethylene insulated polyethylene sheathed power cable

Aluminum cross-linked polyethylene insulated polyethylene sheathed power cable

YJV22
YJLV22

Copper core cross-linked polyethylene insulated steel tape armored polyvinyl chloride sheathed power cable

Aluminum core cross-linked polyethylene insulated steel tape armored polyvinyl chloride sheathed power cable

YJV23
YJLV23

Copper core cross-linked polyethylene insulated steel tape armored polyethylene sheathed power cable

Aluminum core cross-linked polyethylene insulated steel tape armored polyethylene sheathed power cable

YJV32
YJLV32

Copper core cross-linked polyethylene insulated fine steel wire armored polyvinyl chloride sheathed power cable

Aluminum core cross-linked polyethylene insulated fine steel wire armored polyvinyl chloride sheathed power cable

YJV33
YJLV33

Copper core cross-linked polyethylene insulated fine steel wire armored polyethylene sheathed power cable

Aluminum core cross-linked polyethylene insulated fine steel wire armored polyethylene sheathed power cable

production scope

model core count Rated voltage U0/U KV
3.6/6 6/6 6/10 8.7/10 12/20 18/20 21/35 26/35

Nominal cross-section of conductive wire core (mm)2)

YJLV
YJV
YJLY
YJY
1 25-500 25-500 35-500 50-300
YJLV32
YJV32
YJLY32
JYY32
1 25-500 25-500 35-500 50-300
YJLV42
YJV42
YJLV43
YJV43
1 25-500 25-500 35-500 50-300
YJLV
YJV
YJLY
YJY
3 25-300 25-300 35-300 -
YJLV22
YJV22
YJLV23
YJV23
3 25-300 25-300 35-300 -
YJLV32
YJV32
YJLV33
YJV33
3 25-300 25-300 35-300 -
YJLV42
YJV42
YJLV43
YJV43
3 25-300 25-300 35-150

Note: The single core cable armor used for AC circuits adopts a non-magnetic special structure and should be carefully selected.
Single core rated voltage 0.6/1kV cross-linked polyethylene insulated polyvinyl chloride sheathed power cable YJV, YJLV

Two core rated voltage 0.6/1kV cross-linked polyethylene insulated polyvinyl chloride sheathed power cables YJV, YJLV, YJV22, YJLV22

Three core rated voltage 0.6/1kV cross-linked polyethylene insulated PVC sheathed cables YJV, YJLV, YJV22, YJLV22