Welcome Customer !

Membership

Help

Anhui Xun'er Instrument Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Article

Anhui Xun'er Instrument Technology Co., Ltd

  • E-mail

    xrybkj@163.com

  • Phone

    15155078600

  • Address

    589 Tiankang Avenue, Tianchang City, Anhui Province

Contact Now
What are the commonly used thermocouples
Date: 2025-03-03Read: 10
  1. K-type thermocouple (nickel chromium nickel silicon)
  temperature range-200 ° C to+1260 ° C
  featureHigh cost-effectiveness, good antioxidant performance, suitable for most industrial applications.
  applicationWidely used in industries such as metallurgy, chemical engineering, and power.
  2. J-type thermocouple (iron copper nickel)
  temperature range: -210 ° C to+760 ° C
  featureHigh sensitivity, low price, but prone to oxidation.
  applicationSuitable for reducing atmospheres and vacuum environments.
  3. T-type thermocouple (copper copper nickel)
  temperature range: -270 ° C to+400 ° C
  featureGood stability, high accuracy, suitable for low-temperature measurement.
  applicationCommonly used in food, pharmaceuticals, and low-temperature engineering.
  4. E-type thermocouple (nickel chromium copper nickel)
  temperature range: -270 ° C to+1000 ° C
  featureThe highest sensitivity, suitable for low-temperature measurement.
  applicationCommonly used in low-temperature laboratories and the refrigeration industry.
  5. N-type thermocouple (nickel chromium silicon nickel silicon)
  temperature range: -270 ° C to+1300 ° C
  featureGood high-temperature stability and strong antioxidant performance.
  applicationSuitable for high-temperature industrial furnaces and heat treatment.
  6. S-type thermocouple (platinum rhodium 10 platinum)
  temperature range: 0 ° C to+1600 ° C
  featureHigh precision, good stability, and expensive price.
  applicationSuitable for high-temperature measurement, such as in laboratories and high-temperature industrial furnaces.
  7. R-type thermocouple (platinum rhodium 13 platinum)
  temperature range: 0 ° C to+1600 ° C
  featureSimilar to the S-type, but with slightly higher thermoelectric potential.
  applicationSuitable for high-temperature measurement, such as in laboratories and high-temperature industrial furnaces.
  8. B-type thermocouple (Platinum Rhodium 30- Platinum Rhodium 6)
  temperature range:+200 ° C to+1800 ° C
  featureSuitable for temperature, with low thermoelectric potential.
  applicationSuitable for high-temperature measurement, such as high-temperature industrial furnaces and glass manufacturing.
  9. C-type thermocouple (tungsten rhenium 5-tungsten rhenium 26)
  temperature range: 0 ° C to+2320 ° C
  featureSuitable for temperature, with good high temperature resistance.
  applicationSuitable for high temperature measurement, such as aerospace and nuclear industries.