1. K-type thermocouple (nickel chromium nickel silicon)
temperature range-200 ° C to+1260 ° C
featureHigh cost-effectiveness, good antioxidant performance, suitable for most industrial applications.
applicationWidely used in industries such as metallurgy, chemical engineering, and power.
2. J-type thermocouple (iron copper nickel)
temperature range: -210 ° C to+760 ° C
featureHigh sensitivity, low price, but prone to oxidation.
applicationSuitable for reducing atmospheres and vacuum environments.
3. T-type thermocouple (copper copper nickel)
temperature range: -270 ° C to+400 ° C
featureGood stability, high accuracy, suitable for low-temperature measurement.
applicationCommonly used in food, pharmaceuticals, and low-temperature engineering.
4. E-type thermocouple (nickel chromium copper nickel)
temperature range: -270 ° C to+1000 ° C
featureThe highest sensitivity, suitable for low-temperature measurement.
applicationCommonly used in low-temperature laboratories and the refrigeration industry.
5. N-type thermocouple (nickel chromium silicon nickel silicon)
temperature range: -270 ° C to+1300 ° C
featureGood high-temperature stability and strong antioxidant performance.
applicationSuitable for high-temperature industrial furnaces and heat treatment.
6. S-type thermocouple (platinum rhodium 10 platinum)
temperature range: 0 ° C to+1600 ° C
featureHigh precision, good stability, and expensive price.
applicationSuitable for high-temperature measurement, such as in laboratories and high-temperature industrial furnaces.
7. R-type thermocouple (platinum rhodium 13 platinum)
temperature range: 0 ° C to+1600 ° C
featureSimilar to the S-type, but with slightly higher thermoelectric potential.
applicationSuitable for high-temperature measurement, such as in laboratories and high-temperature industrial furnaces.
8. B-type thermocouple (Platinum Rhodium 30- Platinum Rhodium 6)
temperature range:+200 ° C to+1800 ° C
featureSuitable for temperature, with low thermoelectric potential.
applicationSuitable for high-temperature measurement, such as high-temperature industrial furnaces and glass manufacturing.
9. C-type thermocouple (tungsten rhenium 5-tungsten rhenium 26)
temperature range: 0 ° C to+2320 ° C
featureSuitable for temperature, with good high temperature resistance.
applicationSuitable for high temperature measurement, such as aerospace and nuclear industries.