E-mail
903092774@qq.com
-
Phone
15655066688
-
Address
Tianchang Economic Development Zone, Anhui Province
Anhui Zhongwangte Cable Co., Ltd
903092774@qq.com
15655066688
Tianchang Economic Development Zone, Anhui Province
Flat cable: Anhui Zhongwangte Cable Co., Ltd
1: Product features and uses: This product has the characteristics of cold resistance, softness, wear resistance, and oil resistance. It is suitable for power transmission lines, control, lighting, and communication lines for mobile electrical appliances such as trains, trolleys, and transmission machinery with special requirements for cold resistance and oil resistance at AC rated voltage of 0.6/1KV and below. This product has been widely used in industries such as metallurgy, electricity, ships, and ports.
Phase separated shielding DingSunnyFlat cables are suitable for use as power cables for frequency converters.
2: Product execution standards
Q/HHTZH007.3, The flame retardant performance test shall comply with the provisions of GB12666.5-90
3: Usage characteristics
1.Rated AC voltage: U0/U 0.6/1KV
Z high working temperature: 105 ℃
Low ambient temperature: Fixed installation -40 ℃
2.The temperature for cable installation and laying should not be lower than -25 ℃.
4: Basic model and name
Table 1
model |
Product Name |
YVFB |
Ding Qing insulated and sheathed flat flexible cable for mobile use |
YVFPP |
DingSunnyInsulated and sheathed copper braided shielded mobile flat flexible cable |
Note: ZR should be added before the flame-retardant flat cable model, and tin plating can be used for the copper wire in the conductor core.
5: Code name and meaning
Table 2
code name |
Meaning of code |
Y |
Mobile series |
VF |
DingSunnyInsulation and sheath |
P |
Copper braided shielding |
B |
Flat type |
6: Main technical indicators
1. The DC resistance of the finished cable conductor (Class R) (in accordance with GB3956 regulations) shall refer to Table 2 in Appendix A.
The insulation resistance at 2.20 ℃ shall not be less than 50M Ω/KM.
3. The finished cable shall withstand an AC 50HZ3.5KV/5min voltage test without breakdown.
7: Basic cable specifications and structural parameters
1. Ding Qing insulated and sheathed power flat cable
core*Nominal cross-section(mm2) |
Conductor structure (Number of roots)*Diameter) mm |
Cable Z with large outer diameter(mm) |
YVFB | ||
2*1.5 |
48*0.20 |
11.4*7.5 |
2*2.5 |
51*0.25 |
14.0×9.0 |
2*4 |
82*0.25 |
15.8×9.5 |
2*6 |
123*0.25 |
18.2×10.8 |
2*10 |
204*0.25 |
21.5×12.5 |
2*16 |
323*0.25 |
24.2×13.9 |
2*25 |
513*0.25 |
28.5×16.2 |
2*35 |
722*0.25 |
31.8×18.1 |
2*50 |
1026*0.25 |
36.6×20.5 |
2*70 |
1406*0.25 |
41.6×23.3 |
2*95 |
486*0.50 |
47.3×26.3 |
2*120 |
608*0.50 |
50.8×28.1 |
2*150 |
760*0.50 |
56.3×31.2 |
3*1.5 |
48*0.20 |
15.8*7.5 |
3*2.5 |
51*0.25 |
18.8×9.0 |
3*4 |
82*0.25 |
21.6×9.5 |
3*6 |
123*0.25 |
25.8×11.3 |
3*10 |
204*0.25 |
32.1×13.2 |
3*16 |
323*0.25 |
34.2×14.9 |
3*25 |
513*0.25 |
42.3×18.2 |
3*35 |
722*0.25 |
46.2×19.1 |
3*50 |
1026*0.25 |
55.8×22.0 |
3*70 |
1406*0.25 |
66.8×26.8 |
3*95 |
486*0.50 |
70.2×28.0 |
3*120 |
608*0.50 |
85.5×36.0 |
3*150 |
760*0.50 |
95.0×35.1 |
4*1.5 |
48*0.20 |
20.5*7.5 |
4*2.5 |
945*0.50 |
25.8×9.0 |
4*4 |
82*0.25 |
29.4×9.5 |
4*6 |
123*0.25 |
34.1×11.8 |
4*10 |
204*0.25 |
40.4×12.9 |
4*16 |
323*0.25 |
45.9×15.6 |
4*25 |
513*0.25 |
54.1×18.1 |
4*35 |
722*0.25 |
58.6×20.2 |
4*50 |
1026*0.25 |
83.0×26.5 |
3×4+2.5 |
82*0.25/51*0.25 |
30.6×10.7 |
3×6+4 |
123*0.25/82*0.25 |
31.0×12.8 |
3×10+6 |
204*0.25/123*0.25 |
35.0×12.9 |
3×16+6 |
323*0.25/123*0.25 |
41.3×15.6 |
3×25+10 |
513*0.25/204*0.25 |
49.1×18.1 |
3×35+10 |
722*0.25/204*0.25 |
64.2×20.2 |
3×50+16 |
1026*0.25/323*0.25 |
80.2×23.4 |
3×70+25 |
1406*0.25/513*0.25 |
85.3×27.2 |
3×95+35 |
486*0.50/722*0.25 |
97.6×29.7 |
3×120+35 |
608*0.50/722*0.25 |
107.1×31.9 |
5*1.5 |
48*0.20 |
25.5*7.5 |
5*2.5 |
51*0.25 |
32.0*9.0 |
5*4 |
82*0.5 |
37.5*10 |
6*1.5 |
48*0.20 |
31*7.5 |
6*2.5 |
51*0.25 |
40.9*9.0 |
6*4 |
82*0.5 |
42.0*10 |
7*1.5 |
48*0.20 |
32.0*7.0 |
7*2.5 |
51*0.25 |
41.0*9.0 |
7*4 |
82*0.25 |
44.0*10.0 |
8*1.5 |
48*0.20 |
38.5*7.8 |
8*2.5 |
51*0.25 |
48.0*8.0 |
8*4 |
82*0.25 |
51.0*10.6 |
10*1.5 |
48*0.20 |
44.5*7.8 |
10*2.5 |
51*0.25 |
59.0*9.0 |
10*4 |
82*0.25 |
65.2*11.0 |
12*1.5 |
48*0.20 |
59.5*8.5 |
12*2.5 |
51*0.25 |
70.0*8.5 |
12*4 |
82*0.25 |
80.2*11.0 |
Last Article: Cold resistant cable: Anhui Zhongwangte Cable Co., Ltd