1、 Closed end BA seriesAC current sensor

1. Product Overview
Application of BA series productsPrinciple of Electromagnetic InductionReal time measurement of AC current in the power grid, using constant current and linear compensation techniques to isolate and transform it into a standard DC signal output. DC12V or 24V safe voltage or AC/DC85-265V voltage supply can be widely used in the field of industrial automation. BA50L is a converterResidual current transformerThe main purpose is to detect the leakage current of the electrical system, which can keep track of the situation of electrical circuits and equipment at any time, and prevent accidents such as fires caused by leakage.

2. Model Description

3. General Technical Conditions

4. Appearance and installation
① Appearance and perforation size of DC12V or 24V power supply models

② AC/DC85-265V power supply model appearance and perforation size

5. Installation method
The installation method can be selected as rail installation or screw fixed installation. The specific operation is as follows:
a、 rail mounting
Choose a suitable location to install the standard DIN35mm guide rail, and then install the BA sensor onto the guide rail;

b、 Screw fixed installation
On the bottom plate of the cabinet, select suitable locations to open two threaded holes corresponding to the fixed holes of the installed sensors; Install the sensor after placing itPositioning screw(Clockwise).

2、 Open type BA series AC current sensor

1. Product Overview
The open type BA series products apply the principle of electromagnetic induction to measure the AC current in the power grid in real time. They use constant current and linear compensation technology to isolate and transform it into a standard DC signal output. DC12V or 24V safe voltage can be widely used in the field of industrial automation.

2. Model Description

3. Technical conditions

4. External dimensions
① BAK20-AI external dimensions

② BAK50-AI external dimensions

3、 Intelligent BA series AC current sensor

1. Product Overview
The intelligent BA series current sensor applies the principle of electromagnetic induction to measure the AC current in the power grid in real time. It adopts constant current and linear compensation technology to isolate and transform it into a standard DC signal output, or transmit the measurement data through RS485 interface (Modbus RTU protocol). DC24V or 12V safe voltage supply can be widely used in the field of industrial automation. BA50L (II) - AI is an AC residual current transformer that mainly detects leakage current in electrical systems. It can monitor the status of electrical circuits and equipment at any time and prevent accidents such as fires caused by leakage.

integrated

split-type
2. Model Description

3. Technical Specifications

4. Appearance and installation
① Integrated type

② Split type

4AcrelApplication scenarios of BA series products:

Industrial automation field:Industries such as petrochemicals, steel metallurgy, cement construction, and rail transit can be used to monitor the current of production equipment in real time, helping workers understand the operating status of equipment, detect abnormal current situations in a timely manner, and ensure the stability and safety of the production process.
Power system: In substations, distribution rooms and other places, the Ankerui BA series current sensors can accurately measure and transmit the current in power lines, providing data support for the operation monitoring, fault diagnosis and protection of the power system, and helping to improve the reliability and stability of the power system.
In the field of architecture:In smart buildings, it can be used to monitor the electricity usage in various areas of the building, achieve energy consumption monitoring and management of equipment such as air conditioning, lighting, elevators, etc., and help building managers optimize energy use and reduce energy consumption costs. For example, in commercial buildings, by monitoring the current data in different areas, the peak and valley periods of electricity consumption in each area can be analyzed, so as to adjust the operating time and power of equipment reasonably and achieve energy conservation and consumption reduction.
Data Center:The stability and safety requirements for power supply in data centers are met by Ankerui BA series current sensors, which can monitor servers UPS、 The current situation of air conditioning and other equipment, timely detection of equipment overload, short circuit and other faults, to ensure the normal operation of the data center.
In the field of new energy:In new energy projects such as distributed photovoltaic power generation and wind power generation, it can be used to monitor the output current of power generation equipment and the current situation of grid connected lines, providing data support for the operation monitoring and energy management of new energy systems, and helping to improve the utilization efficiency and grid stability of new energy.