Installation and usage guide for traditional Chinese medicine sulfur dioxide detector
Date: 2019-08-28Read: 12

Installation and Use Guide for Sulfur Dioxide Detector

Step: Insert the adapter into a power outlet and connect the DC port to the instrument power interface.

Step 2: Turn on the power switch of the instrument.

Step 3: Run the data acquisition software program, set the software parameters, or directly set the data acquisition parameters on the instrument without connecting to a computer.

Step 4: Place the control sample into the corresponding channel and conduct a control test.

Step 5: Place the test sample into the corresponding channel, set the sample name, and perform sample testing.

Step 6: Manage the saving, deleting, printing, exporting, and uploading of result lines.

  Introduction to Food Safety Comprehensive Analyzer

Product composition and description

This instrument adopts the standard method and performs quantitative analysis based on the principle of Lambert Beer law, using unknown concentration samples and known concentration standard substances. The expression of Lambert Beer's law is as follows: A=- logT=bc, where A represents the absorbance of the substance; T - transmittance of the substance; The absorption coefficient of a substance; B - Optical path length; C - the concentration of a substance.

The instrument consists of an LED cold light source, a colorimetric cell, a photodetector, a photoelectric sensor, a microprocessor, and a micro printer. It can directly display the content of harmful substances in the tested sample on the LCD screen and print out the analysis results. At the same time, it can be operated online with a computer through a USB interface and monitored through a monitoring network system for statistics, summary, analysis, and monitoring.

Instrument functions and points

(1) Multi channel optical system for rapid detection of multiple samples simultaneously.

(2) Adopting a new instrument structure, without mechanical moving parts, anti-interference and anti vibration, with high detection accuracy and long instrument life.

(3) Large screen color LCD Chinese display, user-friendly operation interface, accurate and intuitive reading.

(4) Adopting a USB interface, it facilitates data storage and movement, and can be directly connected to a computer at any time to achieve data query, browsing, analysis, statistics, printing, and information publishing.

(5) Degree of automation: The instrument can automatically diagnose system faults.

(6) Automatically save detection results, with large data storage capacity and built-in micro printer that can print detection results in real-time.

(7) Provide spare accessory configurations, using beautiful and durable aluminum alloy packaging boxes.

(8) Equipped with a large capacity rechargeable battery, it can work continuously for 4 hours without an external power source.

(9) Sample pre-treatment is convenient.

  Operating Instructions for Data Collection Instruments

(1) Insert the power adapter into a 220V power outlet, and connect the DC socket of the adapter to the power interface of the instrument to power on the instrument.

(2) Press the switch on the back of the instrument to turn on the power and start the instrument. Before connecting the power, please check the sample room and do not place colorimetric dishes or other foreign objects; Close the door cover of the sample chamber.

(3) After connecting the instrument, it performs a self-test and displays the self-test interface. At this point, please note that if the instrument fails the self-test, it will automatically display a message indicating that the self-test did not pass. You can turn it off and then turn it back on. If the self check still fails, please contact the merchant; After passing the self check of the instrument, it will automatically enter the interface of the main menu for selecting detection items. 【 Note 】: After entering the detection item selection interface, it is recommended to preheat the instrument for 10 minutes to ensure that the light source is stable before starting the measurement.