150 channel DC current 0-300mA acquisition instrument, successfully applied, Shanghai * company
Date: 2016-07-01Read: 10

YK-Tseries

Intelligent isolation multi-channel voltage and current detector

(Engineer Instructions)

1、 Overview of Intelligent Isolation Multi channel Voltage and Current Collector

(1)YK-TThe series of intelligent isolated multi-channel voltage and current detectors use microprocessors for control and calculation, and can meet various measurement range requirements with different transformers. They can display, control, and transmit voltage and current with high precision. Mainly suitable for testing solar energy and new energy batteries.

(2)adopt128×64Dot matrix LCD, displaying eight channels per screen and looping. It can also be used10.2The inch LCD touch screen displays multiple data channels simultaneously.

(3)Can be equipped with computer acquisition software to collect, record and store data, curve trends, report printing, etc., using open database connectionsODBCsupportSQLStandard database access enables data exchange between computer collection software and standard databases, eliminating the need for users to do software underlying drivers.

(4)Isolation devices are importedMOSFETOptoelectronic relay, unlimited service life for switch switching, isolation detection voltage1200VACms.
(5)Each channel has an independent power supply system, and each channel is independentADCollection design, one channel failure will not cause other channel failures. Each channel can measure different load currents separately.
(6)Fast collection time, the system is designed for every16One acquisition board is connected, and the conversion time for all channels of each acquisition board is less than1In seconds.

2、 Main technical indicators of intelligent isolation multi-channel voltage and current collector

Basic error:0.2FS±1a character

apparent Display: LCD screen display

AC current input

DC current input

0Direct input

0Direct input

52000AEquipped with current transformer input

52000AEquipped with current divider input

AC voltage input

DC voltage input

0500VDirect input

0500VDirect input

5002000VEquipped with voltage transformer input

5002000VEquipped with voltage transformer input

Communication output: interface mode Isolation communication interfaceRS485/RS232

Baud rate1200~9600bpsInternal free setting

electricity Source: Switching power supply 85265VAC

merit Consumption:50W

Ambient temperature050

ambient humidity:<85RH

3、 Operation instructions for intelligent isolation multi-channel voltage and current collector

(1) Key function

When setting the stateUsed to exit the setting state.When there is an alarm in the working state, press this key to switch between the alarm screen and the data display screen.

En- Parameter setting key,When setting the state, it is used to store the new set value of the parameter and enter the next set parameter.

▲ - Set value increase key,When setting the stateUsed to increase numerical values.

▼ - Set value increase key,When setting the stateUsed to reduce numerical values..

(2) Power on self-test

⑴ Connect the power, input, output, alarm and other wiring of the instrument according to the terminal wiring diagram of the instrument.

Carefully check the wiring of the instrument, and only turn on the power after it is correct.

3)Parameter Settings

(1)If during the setting process12Do not change parameters for seconds,The instrument automatically returns to operation. If pressed during the setting processThe key and instrument can also exit the setting state

(2)pressEnKey, display 'Enter Password' 800”Using ▲ orThe key will800Set as808,press againEnkey,Just entered the parameter setting state, inputting other values is invalid to prevent non-technical personnel from misoperation. After setting a parameter, pressEnPress the key to set the next parameter.

(3)Inspection route: Set the number and range of channels for instrument input1128, factory value80.

(4)Set the decimal places and range for each channel03, factory value3

(5)Set the lower range limit and range for each channel-99999999, factory value0.000

(6)Set the upper range limit and range for each channel-99999999, factory value3.000

(7)Set zero correction for each channel, with a correction value range of ±0.999The factory value is set to0, indicating instrument * correction. Display value=actual measured value+corrected value.

(8)Set the full-scale correction for each channel, with a correction value range of0.5002.000The factory value is set to1.000, indicating instrument * correction.After correction, the displayed value is FSEt × (measured value before correction+oSEt), and the factory value FSEt is 1.000.

(9)Communication address, the communication address number of the instrument, with a range of1~99.

(10)Baud rate, with a range of1200~9600.

(11)Display unit, set display unit, do not display unit when empty. Please specify when placing an order for special units.

(unitless)

m3

m/h

L/m

KN

W

ppm

Pa

%

Kg

T/h

m/s

V

KW

N

KPa

m

Hz

L/h

T/s

A

VA

MPa

T

KHz

m/m

L/s

mV

KVA

Bar

L

RPm

T/m

mm

mA

PH

Done setting, over2The instrument panel will start working in seconds.

The prompt settings may change according to user requirements, with additions or deletions in content to meet personalized needs and facilitate simple user use.

4、 Model Description of Intelligent Isolation Multi channel Voltage and Current Collector

YK-T

Intelligent multi-channel voltage and current inspection instrument

Product Category Code

19LCD

LCD inspection display

LCD

touch screen display

input channel

1-150road

input type

AV

AC voltage input

DV

DC voltage input(Can be equipped with splitter input)

AA

AC current input

DA

DC current input

input range

The unit of current isAThe voltage unit isV

Communication output

R

Serial communicationRS232

S

Serial communicationRS485

X

433Mwireless communication1000Within meters

P

Micro printer, printing measurement data

power supply

220VACpower supply

W

DC24Vpower supply

Example of options: YK-T19LCD-150-DA-S

Intelligent channel inspection device, LCD display, input150Road, DC0-5.000A, withRS485Communication,AC220Vpower supply

Note:1~32Road signal input, instrument size: width405mmdeep385mmhigh135mm

33~150Road signal input, instrument size: width400mmdeep445mmhigh300mm

5Intelligent isolation multi-channel voltage and current collectorterminal wiring

5、 Communication instructions for intelligent isolation multi-channel voltage and current collector

(1)This instrument can be equipped with RS232 and RS485 interfaces for direct communication with a computer. The RS485 standard communication distance is 1.5km, and multiple instruments can be attached. The RS232 standard communication distance is 15m, and only one instrument can be attached. The TXD, RXD, and GND of the RS232 interface are respectively connected to the second, third, and fifth pins of the computer serial port. The data format consists of 1 start bit, 8 data bits, no checksum, and 1 stop bit. To avoid communication conflicts, the instruments are all in listening mode. The computer sends a command to a certain instrument at a specified address, and then waits for a period of time for the instrument to respond. After the instrument receives the correct command, it sends out the data. After sending, the instrument is in listening mode again. In the same system, instrument addresses cannot be the same, and baud rates must be consistent.

(2)The instrument adopts the standard Modbus rtu communication protocol. When using the configuration software, the device to be selected is a Modicon (* Kang) PLC, Modbus RTU address type, with function numbers of 3X or 4X, and data of integer 16 bits. The Kingview software register starts from 0001 or 0000 (i.e. 4X001, 4X000), while other configuration software may start from 3x001 or 3x000. The communication is an integer, and users need to handle the decimal places according to the actual situation. Communication transmission data is signed integer data, and it is recommended to define signed integer data for user programming. When the data is greater than 0X8000, the actual negative value is obtained by adding 1 in reverse. For example, if the communication transmission data is 0XFFFF, the corresponding data value is -1. For long integer data such as cumulants, the data value is equal to the high-order x 65536+low order. During configuration, users can also choose the data type as long, and the system will automatically calculate the cumulative amount.Register correspondence table (please refer to the setting section of the operating instructions for specific meanings)

4x001

01Road measurement value

4x002

02Road measurement value

4x003

03Road measurement value

┄┄

┄┄

4x149

149Road measurement value

4x150

150Road measurement value

(3)Format of commands for reading data and sending commands on the upper computer(Suggest reading no more than once0X10namely16A data)

Mailing Address

function number

Starting address high bit

Low order starting address

High number of data bits

Low number of data points

High bit of verification code

Low bit of verification code

01

03

00

00

00

03

05

CB

Data format returned by the instrument

Mailing Address

function number

number of data

*High bit data

*Low bit data

Second data high bit

Second data low bit

The third data high bit

Low position of the third data

High bit of verification code

Low bit of verification code

01

03

06

03

E8

03

E8

03

E8

C1

9F

Format of data writing and sending commands on the upper computer

Mailing Address

function number

Register Address High Bit

Low bit register address

high-order data

data

low position

High bit of verification code

Low bit of verification code

01

06

00

20

00

0C

88

05

Data format returned by the instrument

Mailing Address

function number

Register Address High Bit

Low bit register address

high-order data

data

low position

High bit of verification code

Low bit of verification code

01

06

00

20

00

0C

88

05

(4)Except for the measured values, all other data can be written.

Example: The read address is1The instrument'sPVPV=1000)Value

Sending data as01 03 00 00 00 01 84 0A

Sending data, 01It is the instrument address,03It's a function number,0000It is the starting address of the register,0001 Read a number,84The0AIt's a verification code

The returned data is01 03 02 03 E8 B8 FA (among which03 E81000)

In the returned data,01It is the instrument address,03It's a function number,02Number of data,03 E8Measurement value,B8 FAIt's a verification code

If you want to read two pieces of data, you can send them01 03 00 00 00 02 C4 0B

Module with communication address248

VI Intelligent isolation multi-channel voltage and current collector quality guarantee

If it is a manufacturing quality problem caused by the factory, the instrument will be repaired free of charge from the date of leaving the factory. If the damage is caused by improper storage and use, the repair cost will be charged. Warranty period of twelve months, warranty35The year must be specified separately.

7、 Intelligent isolation multi-channel voltage and current collector ordering instructions

Dimensions of external instruments, opening size, insertion depth

Input signal type and display format

Output type and output method

Communication selection

Feed current size and voltage, power supply for sensors

Instrument power supply

Customized according to customer requirements.

1. Moving on to the main topic, below is a product image introduction

2. The customer is a manufacturer of incubators. They put 150 products into the incubator, heated them to 80 ℃, and powered on the 150 products to test whether they can work normally at 80 ℃. Our product is designed to measure the current of these 150 products. And transmit the measurement data to the PLC.

The following pictures are feedback from the customer on-site to our company

There are a total of 15 drawers, each containing 10 products.