1、 Brief introduction:
Intelligent temperature and humidity alarm is a small temperature and humidity alarm that integrates data collection and control. Applied to the collection, detection, and monitoring of temperature and humidity sensor networks. The intelligent temperature and humidity controller is a temperature and humidity monitor specially developed for the fields of computer rooms, agriculture, forestry planting, and animal husbandry. This controller combines computer rooms, agriculture, and animal husbandry The characteristics of agriculture and forestry planting fields have adopted computer technology and advanced digital temperature sensor technology, overcoming the traditional analog temperature Sensors (such as thermistors, platinum resistors, etc.) have serious defects such as instability, large errors, susceptibility to interference, and the need for regular calibration. This instrument has stable measurement data, high accuracy, and strong anti-interference ability. It has broad application prospects in fields such as computer rooms, agricultural greenhouses, grain depots, forestry, and flower farming.
Widely used in
·Agricultural greenhouse
·Monitoring of temperature and humidity in the computer room environment
·HVAC, Building Automation
·Instrument, medical, food and other industries
·Temperature and humidity monitoring of workshop warehouse
·Hospital Archives Museum
2、 Technical parameters:
power supply12VDCor5VDCSensing element: * Digital temperature and humidity sensor
Moisture measurement range:0~RH
Temperature measurement range: Integrated:0~+60℃
Split body:-40~+120℃(Probe section)
precision Humidity Z can reach a high level±2.0%RHtemperature±0.3℃(25℃)
3、 Wireless temperature and humidity selection:
type score |
say bright |
||||
YK-34 |
|
Intelligent temperature and humidity controller |
|||
|
Product Category Code |
B |
|
wall-mounted |
||
G |
|
pipeline-style |
|||
controlled output |
|
T1~T2 |
Temperature relay control1~2a |
||
|
H1~H2 |
Humidity relay control1~2a |
|||
|
FM |
Buzzer alarm |
|||
|
R |
|
Serial communicationRS232 |
||
S |
|
Serial communicationRS485 |
|||
Power supply for transmitter distribution |
V5 |
DC5V |
|||
V12 |
DC12V |
||||
4、 Terminal wiring
Wiring definition: Right side wiring: power red+, Black-On the left is the sensor probe. Middle: The two yellow lines are the normally open contacts of the upper limit relay for temperature, and the two green lines are the normally open contacts of the lower limit relay for humidity.RS485: White+(A), Blue-(B).
5、 Operating instructions
SET- Parameter setting key, used to store the new set value of the parameter and enter the next set parameter when in the setting state.
▲ - Set value increase key, used to increase the numerical value in the set state. In working mode, press this key to silence the buzzer.
▼ - Set value increase key, used to decrease the value when in the set state. In working mode, press this key to silence the buzzer.
The parameter settings are as follows:
hold downSETThe key remains unchanged1In seconds, a prompt appears:cd-, corresponding value:800Use the ▲ or ▼ keys to800Set as808,press againSETThe key only enters the parameter setting state, and entering other values is invalid to prevent non-technical personnel from misoperation. After setting a parameter, pressSETPress the key to set the next parameter.
(1)appearAdrWhen setting the communication address and range1~99.
(2)appearbdThe baud rate and range of the communication instrument1200~9600.
(3)appearLbtime,Digital filtering parameters, set within the range of0~20.LbThe larger the value, the more stable the measurement, but the slower the response. Generally, when the measured value is subjected to significant interference, it can gradually increaseLbAdjust the values so that the fluctuation between measured values is less than2~5One word. When conducting metrological calibration of instruments in the laboratory, it is necessary toLbset to0or1To improve response speed.
(4)AppearingtHWhen setting the temperature upper limit alarm value (default)30).
(5)AppearingthWhen setting the temperature upper limit alarm reset value (default)29.9).
(6)AppearingtLWhen setting the temperature lower limit alarm value (default)10).
(7)AppearingtlWhen setting the temperature lower limit alarm reset value (default)10.1).
(8)Appearingt0When setting the temperature zero correction value (default)0)The corrected display value=Original display value+ t0Value.
(9)AppearingtFSet the temperature full-scale correction coefficient (default)1)The corrected display value=Original display value ×tFValue.
(10)AppearingrHWhen setting the humidity upper limit alarm value (default)70).
(11)AppearingrhWhen setting the humidity upper limit alarm reset value (default)69).
(12)AppearingrLWhen setting the humidity lower limit alarm value (default)30).
(13)AppearingrlWhen setting the humidity lower limit alarm reset value (default)31).
(14)Appearingr0When setting the humidity zero correction value (default)0)The corrected display value=Original display value+ r0Value.
(15)AppearingrFWhen setting the humidity saturation correction factor (default)1)The corrected display value=Original display value ×rFValue.
(16)appearbsLAt this time, the temperature corresponds to the lower limit of the transmission output.
(17)appearbsHAt this time, the temperature corresponds to the upper limit of the transmission output.
(18)AppearingCJWhen setting the alarm, the linkage mode of the relay is selected for temperature or humidity shared upper limit alarm and temperature or humidity shared lower limit alarmHL, used for temperature independent upper or lower limit alarm, humidity independent upper or lower limit alarm selectiontr.
Parameter settings completed, displayEndExit the setting state and enter the measurement state.
6、 Alarm instructions
① Set asOFFWhen the temperature upper limit exceeds the limit and an alarm is triggeredJ1The light is on, and when the humidity upper limit exceeds the limit, an alarm is triggeredJ1The light is on, and at the same time,J1The normally closed contact of the alarm relay(A pair of red wires in the wiring)From open to closed.
When the lower temperature limit exceeds the alarmJ2The light is on, and when the humidity lower limit exceeds the limit, an alarm is triggeredJ2The light is on, and at the same time,J2The normally closed contact of the alarm relay(A pair of black wires in the wiring)From open to closed.
②Set asOnWhen the upper temperature limit exceeds the alarm or the lower temperature limit exceeds the alarmJ1The light is on,J1The relay is closed.
When the upper humidity limit exceeds the alarm or the lower humidity limit exceeds the alarmJ2The light is on,J2The relay is closed.
After the alarm is triggered, the buzzer will beep, and pressing the ▲ or ▼ keys will silence it.
Intelligent digital temperature and humidity sensor
1、 Brief introduction:
YK-WSThe series of intelligent temperature and humidity sensors adopts the SHTXX series digital temperature and humidity sensors imported from Switzerland. Applied to the collection, detection, and monitoring of temperature and humidity sensor networks.The digital temperature and humidity sensor is a temperature and humidity sensor specially developed for the fields of computer rooms, agriculture, forestry planting, and animal husbandry. This sensor combines computer rooms, agriculture, and animal husbandry The characteristics of agriculture and forestry planting fields have adopted computer technology and advanced Swiss digital temperature and humidity sensor technology, overcoming the traditional analog temperature Sensors (such as thermistors, platinum resistors, etc.) have serious defects such as instability, large errors, susceptibility to interference, and the need for regular calibration. This sensor has stable measurement data, high accuracy, and strong anti-interference ability. It has broad application prospects in fields such as computer rooms, agricultural greenhouses, grain depots, forestry, and flower cultivation.
IITechnical Specifications:
power supply3.3~5.5VSensing element: * Digital temperature and humidity sensor
Moisture measurement range:0~RH
Temperature measurement range: Integrated:-20~+60℃
Split body:-40~+120℃(Probe section)
Accuracy: Humidity Z can reach up to ± 2.0% RH, temperature ± 0.3 ℃ (25 ℃)
3、 Temperature and humidity selection:
type score |
say bright |
||||
YK-WS |
|
Digital temperature and humidity sensor |
|||
|
Product Category Code |
B |
|
wall-mounted |
||
G |
|
Pipeline type (stainless steel) |
|||
O1 |
|
4-20mA |
|||
O2 |
|
0-10mA |
|||
O3 |
|
1-5V |
|||
O4 |
|
0-5V |
|||
O5 |
|
0-10V |
|||
|
R |
|
Serial communicationRS232 |
||
S |
|
Serial communicationRS485 |
|||
Power supply for transmitter distribution |
24V |
DC5V |
|||
V12 |
DC12V |
||||
4、 Terminal wiring
Wiring definition: Right side wiring: power plug. On the left is the sensor probe. Middle: The yellow line outputs positive temperature, while the white line outputs negative temperature. Green line humidity output is positive, blue line humidity output is negative.
SHT10
SHT11
SHT15