Brief Introduction

2、 Scope of application

It can receive input signals such as switch values and level pulses, and is used in industries such as machine tools, textiles, printing, food, packaging, and complete control to record and control quantities.

IIIFeatures

Compatible with both switch quantity and level pulse input signals

Multiple protection, isolation design, strong anti-interference ability, high reliability

A good software platform with secondary development capabilities to meet special functions

Set the count value arbitrarily within the display range, and the set value and current count value will not be lost in case of power failure.

4、 Main technical indicators

Accuracy: ±1a character

Display range:0-999999

Alarm mode and sensitivity are optional, and the relay contact capacity is220V/3A(obstructive)

Pulse amplitude low level:-30+0.6VHigh level:+4V+30V

Manual reset or external signal reset

The counting pulse input can be disabled through the gate control terminal (gate control pause function)

5Button Function

When in working mode, press this key to reset the count value to zero. Short circuit the reset terminal to ground to reset it.

When in working mode, press this key to print instantly.

EnWhen setting the state, it is used to store the new set value of the parameter and enter the next set parameter.

▲ - Used to increase the set value when setting the state;

- Used to reduce the set value when setting the state;

6、 Participate inNumber setting

In working conditionPVDisplay measurement values,SVDisplay the total cumulative value.

pressEnKey, display prompt in the upper row-Cd-The lower row appears800Using ▲ andThe key will800Set as808Press againEnThe key only enters the parameter setting state, and entering other values is invalid. This is mainly to prevent non operators from accidentally modifying parameters on site.

1dot1Factory default settings:dot1=0; K1=1; dot2=0; K2=2;

At this point, input two pulse counts as1, i.e. display value=count value x(K1/K2)

2K1: CoefficientK1K1The decimal places are determined bydot1decision.

3dot2: CoefficientK2The number of decimal places.

4K2 coefficientK2The instrument coefficient isK1/K2Instrument display value=count value×K1/K2.

(5)J1HA- Set value of relay alarm point.

(6) tSRelay alarm delay reset time, unit: seconds, set as0It does not automatically reset and needs to be manually reset to zero.