05.07,202113
~1、 Application of Wet Leakage Current Testing System for Photovoltaic Modules
The wet leakage current test system for photovoltaic modules tests the insulation performance of the modules under humid working conditions, detecting whether moisture from rain, fog, dew, or snow has entered the working parts of the internal circuits of the modules, causing corrosion, leakage, and non safety accidents. The photovoltaic module wet leakage current testing system is a specially designed wet leakage current testing device for the solar photovoltaic module industry.
2、 Composition of Photovoltaic Module Wet Leakage Current Testing System Equipment
Experimental sink
Temperature controlled sink
Heating system
Spray device
Control cabinet
Surface tension tester
Conductivity meter
Programmable insulation withstand voltage tester
3、 Basic description of wet leakage current test system for photovoltaic modules
Model: KM-PV-SLD
The equipment of the wet leakage current test system complies with the specifications and standards of IEC 61215:2005, IEC 61646:2008, and IEC 61730-2:2004.
The equipment can freely set the heating range of the test liquid
Digital display of real-time temperature value
The equipment is equipped with a water level gauge that can directly observe the water level
4、 Specification for Wet Leakage Current Test System for Photovoltaic Modules
Experimental water tank: 2100mm * 1600mm * 200mm.
Heating sink: 1200mm * 600mm * 500mm.
Thermostatic water bath: constant water temperature of 22 ℃± 3 ℃
L can detect the largest component of 2000mm * 1500mm.
This equipment is equipped with a 10 meter head submersible pump
Equipment weight: approximately 150kg
Power requirement: single-phase AC220V ± 5% 25A
Liquid resistivity:<3500 Ω· cm
5、 Technical specifications of wet leakage current test system for photovoltaic modules
Testing method: Platinum plate method
Operation mode: fully automatic operation
Test range: 0-199mN/m
Measurement resolution: 0.1mN/m (note: resolution only does not mean this value can be measured)
Measurement accuracy: 0.2mN/m (standard error value of platinum plate method)
Temperature range: room temperature (if temperature control is required, two components, a constant temperature bath and a constant temperature sample bath, must be equipped)
Container capacity: 15mL minimum
Voltage: Standard AC220V, 1A
6、 Quality Assurance of Wet Leakage Current Test System for Photovoltaic Modules
The company has passed the quality management system certification and strictly follows the management system to organize the design and production of products. It is a Jiangsu Province quality service integrity AA * brand enterprise.
On site installation and debugging of equipment, and training of operating personnel for customers.
If the product cannot function properly due to manufacturing quality issues within twelve months from the date of shipment, provided that the user complies with the product installation and usage rules, our company will provide free repairs for the user.
For products outside the warranty period, our company provides long-term technical services.