Glass rotor flowmeterIt is currently a commonly used type of flow meter in industry. The selection of glass tube float flowmeter mainly depends on several aspects: temperature, pressure, medium, medium density, flow range, connection form, etc.
The temperature of the glass rotor flowmeter is between -20 and 120, but if it is a rotor flowmeter lined with PTFE, it cannot reach such a high temperature.
The main component of a glass rotary flowmeter is the scale tube made of glass, so there must be a pressure limit, and the pressure resistance of glass tube rotary flowmeters with different diameters is also different. In terms of flow range, the normal commonly used flow rate is generally at 2/3 of the maximum flow rate of the scale tube. Although it is simple, there will be different selection of parameters that are not used, and the selection will also vary with changes in conditions