E-mail
99495079@qq.com
-
Phone
13882197191 或者 18081927191
-
Address
No. 4-14, Building 3, No.1 Yinxing Road, Jinniu District, Chengdu City
Chengdu Litong Technology Co., Ltd
99495079@qq.com
13882197191 或者 18081927191
No. 4-14, Building 3, No.1 Yinxing Road, Jinniu District, Chengdu City
The Nernst Embedded Zirconia Trace Oxygen Analyzer is the 7th generation trace oxygen analyzer designed and manufactured by Nernst. This analyzer is widely used in multiple fields, including but not limited to vacuum welding furnaces, chip manufacturing in the electronics industry, reflow soldering, glove box oxygen measurement, 3D printing, biopharmaceutical industry, precision component bright annealing furnaces, high-strength alloy tool coating processing equipment, as well as various small equipment process fields that require oxygen control. The range of measured micro oxygen content can reach 10 ^ -30~100% oxygen content. The analyzer can provide real-time O2% content (percentage) of flue gas in the furnace or flue, as well as 12 other useful parameters. In addition, this trace oxygen analyzer is also suitable for other fields that require high-precision measurement of oxygen content.
feature
Direct insertion fast response zirconia sensor
The Nernst zirconia sensor adopts sheet zirconia ceramic welding and fastening composite technology, which has strong thermal shock resistance.
Generally, standard gas calibration is not required (environmental air calibration can be used), with high oxygen measurement accuracy, fast reaction speed, no signal drift, and strong corrosion resistance.
The actual reaction time is less than 100 milliseconds, and the reaction time for oxygen is 50 milliseconds.
Accurate sensor temperature control
The sensor comes with a built-in heater component, which is precisely controlled by the analyzer to keep the sensor at 720 ℃ at all times.
Large oxygen measurement range and high oxygen measurement accuracy
The range of measured micro oxygen content can reach 10 ^ -30~100% oxygen content.
maintenance-free
The analyzer does not require any regular maintenance, and the sensor does not need to be calibrated on a regular basis, only as needed.
compact design
The analyzer has a small volume, is easy to install, can be installed on the surface of the control panel, and integrated into various equipment components.
output control
The analyzer provides a 4-20mA current output and a computer communication interface RS232 or a network communication interface RS485.
display function
Adopting an easy to read high brightness LED display screen, it can display various functions and parameters, and has strong output and control functions.
Oxygen display unit
It supports automatic conversion of percentage content%, PPM mode, and Scientific notation X-E%.
Alarm Settings
The analyzer is equipped with 3 universal alarm outputs, including 1 high oxygen alarm, 1 low oxygen alarm, and 1 programmable fault alarm.
Automatic or fixed range measurement
The analyzer can be configured to automatically change the measurement range based on the concentration of oxygen during the process.
easy to operate
The analyzer is set up at the factory and users can directly enter the menu to change configuration parameters through the buttons on the analyzer panel.
Sensor specifications and parameters
| parameter | Details |
| Sensor Model | N301 |
| sensor type | High precision zirconia sensor |
| accuracy | Measurement accuracy ± 0.5 ppm, repeatability accuracy ± 0.2 ppm |
| response time | <100 milliseconds |
| heating time | 10 minutes to reach working temperature |
| Sensors can withstand pressure | Positive pressure: 500kpa, negative pressure: 1 Torr |
| Sensor connection interface | M18 × 1.5 thread |
Analyzer specifications and parameters
| parameter | Details |
| Analyzer model | N3100 |
| Type of analyzer | Embedded zirconia trace oxygen analyzer |
| operating range | 0-10ppm, 0-100ppm, 0-1000ppm, 0-10000ppm, 0-5%, 0-10%, 0-100%, 可调 |
| display | 60 × 32mm LED LCD display |
| power supply | 85V~240V AC 3A |
| Temperature and humidity of the installation environment for the analyzer | -25~50℃,5%~95% RH |
| Analog current output | Linear 4-20mA DC output (maximum load 600 Ω) |
| relay output | Three alarm relays, including high and low oxygen alarms, and fault alarms (programmable) |
| 通信端口 | RS232 (optional percentage or PPM), RS485 |
| Protection level | IP65 |
| warranty | 12 months from the date of shipment |
| weight | Analyzer 1.2kg/sensor with outer protective tube 170g |