Humidity ChamberWidely used in industries such as aviation, aerospace, electronics, and ship instruments for accelerated wet heat testing, alternating wet heat testing, and constant wet heat testing of electronic and electrical products, material components, equipment, etc. It can also be used for high and low temperature routine testing, low temperature storage, etc., in order to evaluate the behavior and performance of test samples under given environmental conditions.
Humidity ChamberExquisite appearance, equipment craftsmanship; Refrigeration technology and equipped with cold end PID regulation technology; Equipped with energy-saving, high humidity, and anti drip technology, * equivalent equipment can save more than 30% electricity; Advanced air duct design ensures temperature uniformity and fluctuation; All core and detailed components are branded; Equipment quality is more reliable, with a longer average time;
model |
SEH-150 |
SEH-225 |
SEH-408 |
SEH-800 |
SEH-1000 |
|
Studio size (cm) |
50×50×60 |
50×60×75 |
60×80×85 |
100×80×100 |
100×100×100 |
|
Dimensions (cm) |
115×75×150 |
115×85×165 |
130×105×170 |
165×105×185 |
170×125×185 |
|
|
sex can |
temperature range |
0℃/-20℃/-40℃/-70℃~+100℃/+150℃/+180℃ |
||||
Temperature Uniformity |
<2℃ |
|||||
temperature deviation |
±2℃ |
|||||
temperature fluctuation |
≤ 1 ℃ (≤± 0.5 ℃, expressed according to GB/T5170-1996) |
|||||
warm-up time |
+20℃~+150 ℃/approximately 45 minutes (unloaded) |
|||||
cooling time |
+20℃~-20 ℃/30min/+20 ℃~-40 ℃/50min/+20 ℃~-70 ℃/60min/(unloaded) |
|||||
humidity range |
(10)20~98%RH |
|||||
Humidity deviation |
±3%(>75%RH), ±5%(≤75%R 上) |
|||||
Temperature Controller |
Chinese color touch screen+PLC controller (self-developed control software) |
|||||
Equipment operation mode |
Fixed value operation, program operation |
|||||
refrigeration compressor |
Imported fully enclosed compressor |
|||||
Humidification water |
Distilled water or deionized water |
|||||
Security protection measures |
Leakage, short circuit, overheating, water shortage, motor overheating, compressor overpressure, overload, overcurrent |
|||||
power supply |
AC380V 50HzThree phase four wire+grounding wire |
|||||
meet the standard |
GB10589-89,GB10592-89,GB11158; GB/T10586-89, GB/T2423.1-2008; GB/T2423.2-2008; GB/T2423.3-2006; GB/T2423.4-2008; GB/T2423.22-2002; IEC60068-2-1.1990; IEC60068-2-2.1974; GJB150.3; GJB150.4; GJB150.9 |
|||||