Welcome Customer !

Membership

Help

Dongguan Saisi Testing Equipment Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Download Materials>Introduction to high and low temperature rapid temperature change test chamber
Download

Dongguan Saisi Testing Equipment Co., Ltd

  • E-mail

    flora187@126.com

  • Phone

    18926849868

  • Address

    Building 1, No. 2 Shuishi Road Street, Jiujiang, Changping Town, Dongguan City, Guangdong Province

Contact Now
Introduction to high and low temperature rapid temperature change test chamber
Date: 2019-05-13Read: 9

High and low temperature rapid temperature change test chamberIt is mainly used to investigate the failure caused by the thermal mechanical properties of various industrial products. When the materials that make up the components of the product have poor thermal matching or high internal stress, temperature cycling tests can cause the product to fail due to mechanical structural defects. The temperature change rate is generally between 5-20 ℃/min, which enables the rapid and accurate reproduction of the environmental conditions of the tested samples. It is generally used for screening tests and failure mode assessments of optoelectronic devices, interconnect circuits, component units, and electronic devices. It is an effective method for discovering product design defects and process issues.

model

SEA-225

SEA-408

SEA-800

SEA-1000

SEA-1500

SEA-2000

Inner box size (W x D x H cm)

50×60×75

60×80×85

80×100×100

100×100×100

100×100×150

100×110×180

Outer box size (W x D x H cm)

115×125×160

125×145×170

145×195×185

155×225×195

250×125×190

260×135×250

inner box volume

225L

408L

800L

1000L

1500L

2000L

Temperature rate

5℃/min、10℃/min、15℃/min、20℃/min。

temperature range

-70℃-180℃

temperature fluctuation

±0.5℃

temperature deviation

±2℃

Temperature variation range

-55℃~+125 ℃ (high temperature at least ± 85 ℃ or above)

remark

The above indicators were tested under no-load conditions with an ambient temperature of 20 ℃± 2 ℃

caster

4The height of the casters (excluding external dimensions) is increased by 50-120mm

observation window

450450mm with heating device to prevent condensation and frosting

test hole

The diameter of 100mm is located on the right side of the box (with the person facing the door)

lighting lamp

35W/12V

Energy saving regulation method

The cold end PID regulation method (i.e. heating without cooling, cooling without heating) saves 40% energy compared to the balanced temperature regulation method

Heating method

Electric heating (triple over temperature protection)

refrigerator

German brand compressor

refrigerant

Environmentally friendly refrigerant R400A+R23

cooling method

Water cooling (water temperature 7 ℃~28 ℃, water pressure 0.1~0.3Mpa) to ensure cooling performance

controller

7Inch color touch screen controller

Operation mode

Program running+constant running

Program capacity

200100 times can cycle, jump, hold, and connect

sensor

PT100

Communication function

RS485 Standard USB

Curve recording function

Touch screen automatic recording

power supply

380V± 10%/50HZ, three-phase five wire (3P+N+G)