CA8230 is a single-phase productPower Quality AnalyzerSuitable for monitoring and diagnosing power quality in single-phase or balanced three-phase circuits in the power grid. Adopting a color LCD display screen, it is currently the highest specification among instruments of the same level. It can display real-time waveform diagrams and harmonic analysis graphics of input voltage and current, and has functions such as motor starting current recording mode, trend chart recording mode, and alarm recording. A true multitasking measurement system that can simultaneously perform functions such as electricity parameter measurement and display, trend chart recording, and alarm monitoring.
CA8230 is easy to operate, compact in design, shock resistant, and provides all measurement functions for monitoring power quality and power. It is a basic entry-level instrument for power quality testing and suitable for electrical field technicians to diagnose power quality.
CA8230 single-phasePower Quality AnalyzerProduct Features:
Voltage measurement range: 660 VAC (true RMS) or VDC
Current measurement range: up to 6500AAC or 1400ADC (depending on the current clamp model), can display the minimum value Min, maximum value Max, average value Avg, peak factor CF, peak value Peak, and K factor of voltage/current, etc
Detectable phase sequence:
Can calculate and display the active power W, reactive power VAR, apparent power VA, power factor PF, and displacement power factor DPF of single-phase or balanced three-phase
Calculate and display the total harmonic distortion rate THD (THD-F and THD-R) of voltage/current
In harmonic mode, it can display the values and percentage rates of each harmonic of voltage and current up to the 50th order
Can capture, store, and display the current waveform and related data of the motor starting process
Can store 8 screenshots:
Built in memory 1MB, used to store trend chart recording data (17 battery parameters optional)
Can capture and record 4096 alarm events (including time stamps)
Equipped with an optical port RS232 communication interface, it can import stored data into a PC via a communication cable
Standard Power Analyzer Transfer (PAT) software, which can be used to configure and set up instruments, import measurement record data to PC, convert data to Excel format, etc
Using 6 nickel hydrogen rechargeable batteries (LR6), with an external AC power adapter, it automatically charges
Application of CA8230 single-phase power quality analyzer product:
Power quality inspection of the main transformer and various power supply circuits in the low-voltage distribution room
Measurement and diagnosis of electrical energy quality for medical equipment, electronic precision equipment, and major production equipment, as well as preventive maintenance and testing
Diagnose and confirm whether the harmonic source is introduced from the power supply end or emitted from the load end
Verification of Power Distribution in Power Supply Circuit
Measure and record the load curve (kW, VAR, VA) of the power system
Energy metering of power supply circuits (kVAh, VARh, kWh) and analysis of energy-saving renovations
Fault analysis of switchgear/distribution panel and other electrical equipment, rotating electrical machinery equipment
Analysis of the Starting Current Process of Electric Motors
Diagnose and confirm the K factor of the power transformer