Precautions for using DC-LWQ gas turbine flowmeter
Date: 2024-10-24Read: 4

DC-LWQPrecautions for using gas turbine flowmeter

DC-LWQPrecautions for using gas turbine flowmeter

  (1)In the system, flow meters are generally installed in open areas of pipelines to reduce the impact of equipment on instruments. Convenient for later inspection and maintenance.

  (2)When there is a high-power motor near the flowmeter, in order to avoid power frequency interference, in addition to adding shielding to the signal transmission cable, the signal transmission method should try to use DC signal.

  (3)When using explosion-proof flow sensors, the instrument equipment casing cannot be opened on site while powered on. During maintenance, attention should be paid to protecting the casing, especially the explosion-proof joint surface, which cannot be damaged.

  (5)The detection components should be regularly removed from the pipeline and cleaned with alcohol or gasoline.

If you encounter any problems during use, please feel free to contact the technical engineer of Guangzhou Dongyi Automation Technology Co., Ltd. at any time