Remember the 7 precautions for installing electronic drain valves
Date: 2013-11-25Read: 10
  Electronic drain valve7 important precautions for installation:
During installationdrain valvePreviously, sludge, copper shavings, rust, etc. in the compressed air system should be removed Suggest emptying the system under full pressure for 3-5 minutes before installing the drainwater valve.
The direction of the second drainage is consistent with the direction of the arrow on the valve body
The voltage of the three power supplies should match the voltage of the drain valve (marked on the coil as the drain valve voltage). Do not connect the wrong power supply
The TEST membrane switch on the four timer is a manual test button, and every time it is pressed, the drain valve discharges once This button is used in daily work to check the drainage condition at any time
The two knobs of the five timer are used to adjust emissions and interval time, and users should make timely adjustments according to climate and working conditions
The small screws on the junction box of the six drainage valves not only have a connecting function, but also have the function of tightly sealing the gasket to prevent water from entering the timer and coil, so they must be tightened Otherwise, the sealing gasket cannot provide waterproofing and may cause the coil and timer to burn out The locking nut of the connector also has waterproof function, so it must be tightened
sevenElectronic drain valveDuring use, there may be situations where the solenoid valve is not tightly closed, resulting in continuous air leakage Usually, this malfunction is not caused by the quality of the drain valve itself. The reason is that the condensed water is too dirty, and the small solid particles in it enter the valve core, causing it to get stuck
  Hangzhou Gaoyan Technology Co., Ltd. (GAOYAN))It is a joint-stock company that integrates the research and development, production, sales, supporting, service, and design, manufacturing, installation, and acceptance of gas pipeline busbar systems. The company has gathered a group of professional talents in the high-purity process transportation industry to provide customers with design, installation, and commissioning services for pressure reducers and their supporting products, as well as the preparation, storage, and transportation systems of high-purity gas media. Simultaneously providing indoor quality control equipment and systems necessary for demanding production environments.