in useHigh Temperature Test ChamberHow to troubleshoot, discover and solve equipment failures that often occur? Next, the editor will share with everyone!
1. In high-temperature testing, when the temperature change does not reach the test temperature value, the electrical system should be inspected and the faults should be eliminated one by one. If the temperature rises slowly, the air circulation system should be checked to see if the regulating damper of the air circulation system is open. Instead, we should inspect the wind energy cycle motor. Is this okay? If there is a serious temperature overshoot, it is necessary to adjust the PID tuning parameters. Due to the direct increase in temperature, the over temperature protection controller malfunctioned and the control instrument must be replaced.
2. WhenHigh Temperature Test ChamberWhen a fault suddenly occurs during the experiment, corresponding fault display prompts and audio alarm prompts will appear on the control instrument. When operating and using control equipment, the operator can quickly check which type of fault it belongs to in the troubleshooting chapter, and then ask professional personnel to quickly troubleshoot to ensure that the test proceeds normally. During the use of other environmental testing equipment, specific phenomena may occur, which need to be analyzed and eliminated. Regularly maintain environmental monitoring equipment, clean the condenser of the refrigeration system, lubricate moving parts according to the instructions, and regularly maintain the electrical control system. Those jobs are very important.
3. If the low temperature of the high-temperature test chamber does not meet the testing criteria, then it is necessary to observe the temperature changes. Is it decreasing slowly, or does the temperature decrease after reaching a certain value? The former method is to check whether the test sample needs to be dried before the low-temperature test, and then put the test sample into the laboratory for further testing. If too many test samples are placed, the test can be carried out. So after eliminating the above reasons, the wind in the studio cannot be recycled. It is necessary to consider whether the refrigeration system is faulty and request professional personnel from Hongzhan Instrument to repair it. The latter situation is due to the harsh environment in which the equipment is used. The environmental temperature and equipment location should meet the requirements.
The above isHigh Temperature Test ChamberHow to troubleshoot and solve problems and malfunctions? I hope it can help everyone. If you have any other questions, please consult the editor! Welcome to leave a message and follow us.