UV aging test chamber

08.22,20237

Brief Introduction

The following is technical information about the 'Photovoltaic UV Aging Box', please refer to:

1、 Product Description of Photovoltaic UV Aging Box
The Wuhan Gaotian Photovoltaic Module UV Aging Test Chamber mainly specifies the test for assessing the anti UV radiation ability of photovoltaic modules when exposed to UV radiation environment. This test is suitable for evaluating the anti UV radiation performance of storage polymer materials, protective layers and other materials;


2、 Detailed specifications
Effective irradiation area: 600 × 1270mm
Component surface temperature: 60 ℃
Temperature fluctuation: ± 0.5 ℃
Temperature resolution: 0.1 ℃
Center distance of the lamp: 70mm
Illumination: The uniformity of the component testing surface is ± 15%
Temperature control method: PID self-tuning temperature control method
Wind speed: 0.5-1 0m/S
UVB-313 wavelength: 280-320nm UVA-340 wavelength: 313-340nm
Light source: 3 UVA and 3 UVB models produced by Q-Panel; Simultaneously using 6 light tubes
Power supply: AC220V 50HZ Total power: 4KW
Standard accessories: 1 sample shelf, 8 light tubes, 1 handheld radiometer


3、 Box making material
The outer shell is made of high-quality (t=1.2mm) A3 steel plate and processed into shape by CNC machine tools. The surface of the shell is sprayed with plastic for a smoother and more beautiful appearance
The interior material uses brushed SUS304B board, which has the characteristics of acid resistance, corrosion resistance, and easy cleaning;
The position of the sample rack can be adjusted up and down as needed;
Since the professional design of experimental equipment based on historical experience, there has been a reasonable air duct circulation system that enables the inside of the box to function properly
Temperature reaches Z high uniformity; '
Distance between the parallel surface of the specimen and the lamp surface: Z meets the irradiance requirements for sample testing (the height of the specimen table can be adjusted)


4、 Supply air circulation system
Snail style fan, characterized by low noise and high efficiency;
Stainless steel multi wing centrifugal wind turbine
The air supply circulation system adopts a single cycle
When the equipment itself generates ozone, it has an exhaust function to discharge the ozone outdoors (when the equipment exceeds the temperature and automatically exhausts to the outside after the equipment test). Customers need to provide a 100mm diameter hard pipe to discharge the ozone outdoors.


5、 Execute components
Fuji small relay
Schneider AC contactors have a mechanical lifespan of up to 20 million cycles and an electrical lifespan of up to 2 million cycles. With TH protection treatment, they can be used in humid and hot environments. Auxiliary contacts, power on/off delay contacts, mechanical locking and other modules can be attached to the product body.


6、 Light source characteristics
The center distance of the lamp is 70mm, and according to the size of solar modules in the photovoltaic industry, the length of solar modules is 1680mm
Calculate the use of 6 light tubes; Two additional UV-A and UV-B fluorescent lamps with a rated power of 40W will be delivered. The ultraviolet fluorescent tube is installed on the top layer inside the instrument.
The emission spectrum energy of UV-A lamps is mainly concentrated at a wavelength of 340nm, while the emission spectrum energy of UV-B lamps is mainly concentrated at a wavelength of 313nm, which is a continuous spectrum roughly distributed between 280-400nm, with an energy ratio of 2:1. '
According to the experiment, the spectral irradiance should not exceed 5 times the corresponding solar irradiance (average sunlight at noon on the equator in summer), and the UV-A irradiance of 40W is almost in line with the requirements. Therefore, the best light source for Z is selected.
Due to the gradual decay of fluorescent light energy output over time, in order to reduce the impact of light energy decay on the experiment, as well as GB/T 19394-2003
No.5-a requires a radiation uniformity of ± 15%. This test chamber is designed with a lamp current control system to obtain a constant output of light energy.


7、 Wuhan Gaotian Photovoltaic Module UV Aging Test Chamber GB/T19394-2003 and GB/T2423.24-1995 Simulated Ground Solar Radiation Test Method


8、 After sales service
1. Installation and commissioning: Our company is responsible for free delivery to the customer's designated location, and will send professional technical personnel for free installation and commissioning. 2-5 operators will be trained until they arrive at the meeting to operate.
2. After sales service commitment: All company products come with a one-year warranty and lifetime maintenance. If there is a problem with the product, we will respond within 15 minutes of receiving the repair report, and our professional maintenance personnel will come to handle it within 48 hours.