Ankerui BAK series open-ended current transmitter
Date: 2025-09-20Read: 2


1 Product Overview

  Ankerui BA cement plant open type AC current transmitterBy applying the principle of electromagnetic induction, real-time measurement of AC current in the power grid is carried out, and constant current and linear compensation techniques are used to isolate and transform it into a standard DC signal output. DC12V or 24V safe voltage can be widely used in the field of industrial automation.Ankerui BA cement plant open type AC current transmitter

2 Model Description

安科瑞BA水泥厂开口式交流电流变送器

3 Technical conditions

安科瑞BA水泥厂开口式交流电流变送器

4 External dimensions

4.1 BAK20-AI external dimensions

Manufacturer's contact phone number 18706162823 (same as WeChat)

安科瑞BA水泥厂开口式交流电流变送器

4.2 BAK50-AI Dimensions

安科瑞BA水泥厂开口式交流电流变送器

5 Wiring methods

安科瑞BA水泥厂开口式交流电流变送器

V+- Positive pole of power supply (note that the positive pole of power supply cannot be connected in reverse to ground)

DO -, DO+- switch interface

V - Power Ground

A. B-485 interface

OUT - Analog output negative

OUT+- Analog output positive

The cable is a perforated input

Definition of indicator light:

RUN: Running normally. When there is no 485 communication connection, the RUN light displays green and flashes once every 1 second; When the current sensor is successfully connected to 485 communication, the RUN light flashes rapidly;

Alarm: After turning on the alarm switch, when the input current reaches 120% of the current sensor range, the red light of the Alarm light remains on, and the relay output is closed; When the input current drops below 110% of the sensor range, the alarm light goes out. If the alarm switch is not turned on, the alarm will not light up and the relay will not close.

Note:

(1) The instrument wiring adopts detachable terminal blocks, and it is recommended to use shielded wires with a cross-sectional area of 0.75mm ² for connecting wires on the power, output, RS485 communication, and switch interface sides.

(2) The specific wiring shall be based on the wiring diagram on the physical casing.