Yesterday afternoon at around 3 o'clock, a customer from Liaocheng, Shandong called and said that they bought a pressure transmitter in July 2012. This pressure transmitter has been very useful and has been installed on the equipment ever since. The pressure value displayed every time is very accurate. However, this morning they found that the meter head displayed garbled characters. They are now calling to ask what is the reason for the garbled characters on this pressure transmitter? After carefully listening to the customer's feedback, we then asked the customer several questions, including power supply, environmental interference, hardware failure, and software parameters. We then asked the customer to first check whether the power supply and wiring had been tampered with according to our requirements, eliminate environmental interference, and then consider hardware or software failure. After about half an hour, the problem was finally solved. The customer was very happy and said that our product is easy to use and the service is really thoughtful. Today we will explain to you: What is the reason for the garbled code displayed on the pressure transmitter?
usuallyWhat is the reason for the garbled code displayed on the pressure transmitter?There are the following points
Firstly, unstable power supply: What is the reason for the pressure transmitter displaying garbled codes? If the power supply voltage is unstable, it may cause the pressure transmitter display to malfunction, resulting in garbled characters. At this point, the problem can be solved by using a voltage stabilizer or replacing the power supply.
Secondly, internal hardware malfunction: What is the reason for the pressure transmitter displaying garbled code? There may be a short circuit or other hardware malfunction inside the transmitter, which can cause the signal to not be read properly and result in garbled text being displayed. In response to this situation, it is necessary to inspect and repair or replace damaged components.
Thirdly, incorrect parameter settings: What is the reason for the pressure transmitter displaying garbled codes? If the parameter settings are incorrect, it may also cause the pressure transmitter to fail to read the signal properly and display garbled characters. Therefore, it is necessary to correctly set and debug the parameters of the pressure transmitter to ensure its normal operation.
In summary, what is the reason for the garbled code displayed on the pressure transmitter? The methods to solve the problem of garbled display on pressure transmitters mainly include: checking and stabilizing the power supply, checking and repairing internal hardware faults, and correctly setting and adjusting parameters.