Advantages, disadvantages, and technical specifications of magnetic flap level gauges
Date: 2019-04-18Read: 9

Magnetic flap level gaugeAdvantages, disadvantages, and performance indicators:
Advantages:
1. The measurement channel is a smooth straight pipe that will not block, suitable for measuring liquid-solid two-phase fluids containing solid particles, such as pulp, mud, sewage, etc.
2. No pressure loss caused by flow detection, good energy-saving effect;
3. The measured volumetric flow rate is actually not significantly affected by changes in fluid density, viscosity, temperature, pressure, and conductivity;
4. Large flow range and wide aperture range;
5. Can be used with corrosive fluids.
Disadvantages:
1. Cannot measure liquids with very low conductivity, such as petroleum products;
2. Cannot measure gases, vapors, and liquids containing large bubbles;
3. Cannot be used for higher temperatures.

Performance indicators:
1. Normal working conditions:
The ambient temperature ranges from -25 ℃ to 70 ℃;
B Relative humidity of 5%~(including condensation and direct humidity);
The atmospheric pressure ranges from 86KPa to 108KPa;
2. Measurement range: 500mm to 6000mm graded;
3. Measurement accuracy: flip column indicator ± 10mm;
4. Working pressure: 1MPa, 1.6MPa, 2.5MPa, 4MPa, 6.3MPa, 10MPa, 16MPa;
5. Medium density: graded from 0.5g/cm3 to 1.8g/cm3;
6. Medium viscosity: ≤ 0.05Pa? S;
7. Medium temperature: -25~80 ℃, (high temperature type 0~200 ℃), (high temperature type 0~450 ℃);
8. Tracking speed: ≤ 0.8m/s;
9. Contact medium material: 1Cr18Ni9Ti polytetrafluoroethylene;
10. Control point error: ± 10mm;
11. Return error: not exceeding the basic error;
12. Repetitive error: not exceeding the basic error;
13. Contact capacity of switch control point: DC24V or AC220V; 1A (pure resistive load);
14. The smallest spacing between control points (mm): 60;
15. Shell protection level: IP65;
16. Display instrument: digital display meter (can set upper and lower limit alarms and output 4-20mA signals);
17. Explosion proof grade: dIICT6.