The hydrogen purity analyzer uses the thermal conductivity method to detect gas purity, and many products suffer from temperature drift problems (i.e., the results of detecting the same gas vary greatly at different ambient temperatures), resulting in significant errors in the test data. Mainly used for daily detection of hydrogen purity in power plant hydrogen cooled generators and hydrogen production stations, and can also be used for monitoring the hydrogen replacement process during the start-up and shutdown of hydrogen cooled generators.
Measurement range: H2 content in the air (0~)
H2 content in CO2 (N2) (0~)
Air content in CO2 (N2) (0~)
Measurement accuracy: 0.1%
Resolution: 0.1%
Measurement time: about 2 minutes
Sampling flow rate: 200-300ml/min
Working temperature: -20 ℃~50 ℃
◆ Working power supply: AC/DC dual-use, lithium battery can work continuously for 8 hours, overcharge protection
◆ Volume and weight: Volume 360 × 260 × 130 (mm), weight 3kg