Electrolytic sodium hypochlorite generator/water plant disinfection equipment
Water is the source of life, and the sterilization and disinfection of tap water are very important for anyone. We need to drink water every day. If the bacteria in tap water are not thoroughly disinfected, it will pose a great threat to our physical health. Therefore, we recommend the sodium hypochlorite generator from Shandong Hechuang Zhiyun Environmental Protection Equipment Co., Ltd.
Electrolytic sodium hypochlorite generator/water plant disinfection equipment
The HCCL type sodium hypochlorite generator device is a chlorine preparation device that has been carefully researched by summarizing the existing equipment and technical characteristics at home and abroad, complementing each other's strengths and weaknesses. Sodium hypochlorite is a strong oxidant and disinfectant, which is produced by extracting refined fine salts from a wide range of inexpensive sources and electrolyzing them without membranes. To ensure the freshness and high activity of sodium hypochlorite texture. To ensure the disinfection effect, this device adds sodium hypochlorite while it is being used. It has the same oxidizing and disinfecting properties as chlorine and its compounds.
Equipment raw material specification requirements:
1. Salt: The salt used for system operation is clean NaCl, which involves hygiene and safety requirements. The raw material used is refined edible salt (excluding iodine), and it is required to meet the standards of Grade I or above of GB 2721 "Edible Salt"; The NaCl content must be greater than 98.5%, and it is required to be prepared as saturated salt water at room temperature and tested for hardness index below 50mg/L (calculated as CaCO3).
2. Water: The operation of the system requires electrolysis of dilute salt water, so the electrolyte needs to be prepared using water. The HCCL type sodium hypochlorite generator is equipped with a soft water system, and the system requires tap water that meets drinking water standards. In particular, the following indicators need to be met:
serial number |
Indicator |
Limit value |
1 |
Chromaticity (Platinum Cobalt Chromaticity Unit) |
1 |
2 |
Turbidity (NTU - Scattering Turbidity Unit) |
1 |
3 |
Visible to the naked eye |
none |
4 |
PH (pH unit) |
6.5~8.0 |
5 |
Total hardness (calculated as CaCO3, mg/L) |
10 |
6 |
铝 (mg/L) |
0.2 |
7 |
Iron (mg/L) |
0.3 |
8 |
锰 (mg/L) |
0.1 |
9 |
Copper (mg/L) |
1 |
10 |
Zinc (mg/L) |
1 |
serial number |
Indicator |
Limit value |
11 |
Chromium (hexavalent, mg/L) |
0.05 |
12 |
Lead (mg/L) |
0.01 |
13 |
Sulfate (mg/L) |
10 |
14 |
Qing compound (mg/L) |
0.05 |
15 |
Fluoride (mg/L) |
0.1 |
The requirement for the hardness of the inlet water is to be below 10mg/L (calculated as CaCO3), and if it exceeds the standard, it needs to be explained and communicated in advance.
We do not assume any responsibility for system malfunctions caused by the use of raw salt and water inlet indicators that do not meet the standards.