Welcome Customer !

Membership

Help

Shandong Puchuang Industrial Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Article

Shandong Puchuang Industrial Technology Co., Ltd

  • E-mail

    puchuang8028@163.com

  • Phone

    18615268674

  • Address

    D2-105, Phase III, Times Headquarters Base, No. 15 Lanxiang Road, Tianqiao District, Jinan City, Shandong Province (1st Floor)

Contact Now
T/HBX 001-2023 Testing Method for Internal Stress of Glass Vessels and Glasses
Date: 2025-10-10Read: 7

The internal stress of glass cups mainly comes from the production process (such as insufficient annealing after melting and forming) - when the glass cools, the temperature difference between the inside and outside is too large, and the internal atomic arrangement is not "relaxed", forming a mutually pulling "internal stress". This kind of stress is an "implicit risk", once it exceeds the glass's bearing limit, it will cause an unforeseen rupture, directly threatening personal safety.

T/HBX 001-2023 "Glassware Glass Cup" is a group standard published by the Glass Industry Association of Hechuan District, Chongqing. Its Article 6.5 clearly specifies the testing method for internal stress of glass cups. According to this standard, internal stress testing must be carried out in accordance with GB/T 15726 "Method for Testing Internal Stress in Glass Instruments". The specific principles, steps, and judgment criteria are as follows:


1、 Testing principle

adoptPolarized light methodEvaluate the magnitude of internal stress by measuring the birefringence phenomenon caused by stress inside the glass. When polarized light passes through glass with internal stress, it will decompose into two beams of polarized light with perpendicular vibration directions, resulting in an optical path difference. The optical path difference is directly proportional to the stress intensity, and the calculation formula is:

2、 Main instruments and equipment

  1. SG-03T Polarization Stress GaugeA polarizer, analyzer, sensitive color plate (such as a 565 nm full wave plate), and stage are required, with an accuracy of optical path difference measurement error of ≤± 2 nm.

202509171049550556.jpg

  1. BTG-01E Electronic Digital Bottle Wall Thickness TesterUsed for measuring sample thickness, with an accuracy of 0.01 mm.

202509171048020266.jpg

3、 Test steps

  1. instrument calibration
    • Turn on the polarizing stress meter, adjust the polarizer and analyzer to the orthogonal extinction position (with a completely black field of view), and record the initial angle deviation.

    • Place a 1/4 waveplate and reset it to zero to ensure that the optical path system is functioning properly.

  2. Sample preparation
    • Select representative glass samples, clean the surface and let it stand for at least 30 minutes to avoid temperature fluctuations affecting the results.

    • Measure the thickness of the flat part at the bottom of the sampleAccurate to 0.01 mm.

  3. Stress measurement
    • Place the sample vertically on the stage, allowing polarized light to pass vertically through the central area at the bottom.

    • Rotate the analyzer and observe the interference color change. When a dark cross or specific interference color appears at the center of the sample, record the rotation angle of the analyzer.

    • According to the formulaCalculate the total optical path difference using a sodium light source with a wavelength of 589.3 nmSubstitute the thickness againObtain the unit thickness optical path difference.

  4. Result determination
    • According to Article 5.3 of T/HBX 001-2023, the internal stress in the glass cup must meet the requirementsRefractive optical path difference ≤ 20 nm/mm.

    • If the test value exceeds this limit, it indicates that the glass annealing process is not up to standard and there may be a risk of cracking.