The function of buried water level monitoring equipment is to monitor water level and rainfall in real time, and to detect and warn of abnormal water level in a timely manner
Model recommendation: TH-JS1Manufacturer of meteorological and environmental monitoring instruments and equipment, Yunjing Tianhe supports customized services for merchants. Choose Shandong Yunjing Tianhe for your peace of mind. The buried water level monitoring equipment is used to monitor water level and rainfall in real time, and can detect and warn of abnormal water level in a timely mannerThe real-time monitoring and early warning system can monitor the rainfall, water level and other data in various areas of the city in real time, and issue warnings based on preset warning thresholds. Once the warning threshold is reached, the system will automatically trigger the warning mechanism and promptly notify relevant departments and personnel. The intelligent linkage supports the edge computing function, which can control the start and stop of drainage pumps, water pumps and other equipment according to the monitoring parameter conditions. The system automatically activates the on-site drainage equipment in a timely manner based on the preset flood prevention parameters, in order to avoid and delay the occurrence of urban waterlogging. Map positioning and information management: Supports GIS map positioning, which can quickly locate the site through map search. By combining data tracking and display, we can intuitively and dynamically observe and understand the relevant information of terminal devices, and achieve information management of system layout. Remote management can be viewed and managed through the cloud platform of information terminals such as Android/iOS phones, computers, tablets, etc., making it convenient for users to monitor monitoring data anytime and anywhere.

1、 Product Introduction
The buried urban waterlogging monitoring system is supported by Internet of Things technology and integrates intelligent sensing and intelligent services into an intelligent monitoring system.
The system consists of a monitoring host, pole support, power supply system, buried water accumulation monitoring device, LED dual color display screen, and cloud platform. It mainly provides real-time monitoring and early warning for urban roads, ground, tunnels, overpasses and other places that are prone to water accumulation.
The system adopts highly integrated integrated water accumulation monitoring equipment to monitor the water level in low-lying sections of the urban area in real time and achieve automatic alarm. By integrating data from various monitoring points, it can grasp the overall water accumulation situation in the urban area and timely carry out drainage scheduling. With the help of this system, the municipal administration departments can achieve regular monitoring, early warning and early preparation, deal with the places where floods may occur due to rainstorm, reduce the probability of urban salvage, and at the same time, do a good job of early warning for the people in the areas where water level rises. The traffic management department can obtain real-time water levels of various road sections through this system, and provide travel guides for the general public through media such as radio and television, avoiding personnel and vehicles from entering deep water sections, reducing economic losses for the public, and ensuring their personal safety.
2、 Application scope
It can be applied to urban management, municipal transportation roads, residential areas, low-lying areas, underground parking lots, logistics parks, agricultural irrigation areas, tourist attractions, and can also be used for smart city construction.
3、 Technical parameters
1. Host part
| power supply |
AC220V |
| power supply method |
Mains or solar power supply |
| Device power consumption |
≤25 W |
| Operating Temperature |
-40~80℃ |
| device interface |
interface type |
Instructions |
| LED screen display interface |
Dual color LED display screen (96 * 16 dots) |
| Upstream 485 acquisition |
485 communication distance of 2000 meters |
| Two way switch interface (reserved) |
Voltage input range: 0-5V |
| Two analog interfaces (reserved) |
Collection range: 4-20mA, 0-5V, 0-10V default 4-20mA |
| One way water immersion detection (reserved) |
Can detect the presence or absence of water |
| Two relay interfaces |
Relay capacity: 250VAC/30VDC 3A. One circuit can be set to active and passive, used for alarm or automatic control |
| Alarm equipment |
Support sound and light alarm |
Support voice broadcasting |
| LED screen |
Size 102cm * 22cm dual color screen |
| Equipment bracket |
2-meter pole |
| control box |
Used for placing remote telemetry terminals and power supplies |
2. Underground water accumulation monitoring device section
| power supply method |
Built in battery power supply (3.6V lithium-ion battery) |
| battery life |
Can work continuously for 5 years without standing water |
| Water level range |
≤1.5m |
| Water level error |
1cm |
| resolution |
1mm |
| output signal |
LORA wireless spread spectrum signal |
| Shell material |
304 stainless steel |
| Protection level |
IP68 |
| Installation method |
Adopting buried installation |