1151GP type remote differential pressure transmitter
Date: 2015-04-22Read: 13
1151GP typetransmitterIt has a very rich variety, which can measure micro differential pressure to large differential pressure, low pressure to high pressure, liquid level, vacuum degree, and specific gravity. Combined with a throttling device, flow can also be measured without using a square root.

Flange type liquid level transmitter, with flat flange and plug-in flange; There are four combinations available for installing flanges: 3 # and 4 #, 150 # (working pressure of 1.89Mpa), and 300 # (working pressure of 4.95Mpa) for users to choose from. In addition to 316 stainless steel, there are also Hastelloy, Monel, and Tantalum materials that can be used in corrosive media.

The 1151GP transmitter uses a metal sealed delta chamber as the sensing element, eliminating the problems of impact resistance and vibration difference when transmitting force mechanically; Eliminate errors caused by external stress and torque, ensure high stability performance of the transmitter, and reduce errors caused by static pressure (13.79Mpa~31.0Mpa); Due to the use of approximately the same external dimensions of the delta chamber for each variety, the entire 1151 series has approximately the same appearance and weight, ranging from the micro differential pressure type measuring 0.12Mpa to the pressure type measuring 41.37Mpa.

1151The transmitter is exquisitely designed with explosion-proof and all-weather structure. Installation, use, and calibration are all very convenient and simple. The wiring terminals and amplification circuits are placed in a sealable electrical chamber at the top, and are separated from each other. So when wiring on site, the amplifier is still working in a sealed state. The amplification circuit has reverse polarity protection to prevent damage to the transmitter due to misconnection. The volume change during operation of 1151 is less than 0.16 milliliters, which can prevent excessive changes in the liquid column of the measured medium. Therefore, there is no need to add a condenser or liquid level cylinder to compensate for the volume change. Using corrosion-resistant materials such as tantalum, Hasloy, and Monel alloys to adapt to the measurement of corrosive media. By using integrated circuit components and plug-in printed circuit boards, there are fewer faults, easier maintenance, reduced spare parts, and lower maintenance costs.

Working principle of 1151GP transmitter

The pressure of the measured medium is transmitted to the central measuring diaphragm through the isolation diaphragm of the δ chamber (LT and DP/GP remote transmitters with 1199 are used to transmit the measured pressure first through an isolation diaphragm and a fully sealed capillary system filled with silicone oil or fluorine oil before being transmitted to the isolation diaphragm of the δ chamber) and the filling oil in it. Except for the AP type pressure transmitter, which measures the vacuum reference point on the other side of the diaphragm, other types of measuring diaphragms have either atmospheric pressure or the low-pressure side of the measured differential pressure. The measuring diaphragm is a pre tensioned elastic element, and its displacement is proportional to the pressure of the measured medium. The largest displacement is only 0.10mm, and the position of the measuring diaphragm is detected by the capacitor fixed plates on both sides. The differential capacitance between the measuring membrane and the fixed plates of the two capacitors is linearly converted into a two-wire current signal of 4-20mADC by the amplification circuit.

This 1151DGP remote pressure transmitter provides users with a reliable measurement method that avoids direct contact between the measured medium and the isolation diaphragm of the transmitter. It is suitable for the following situations:

(1) When the measured medium has a corrosive effect on the transmitter connector and pressure sensing element;

(2) When it is necessary to isolate the high-temperature measured medium from the transmitter;

(3) When there are suspended solids or high viscosity in the measured medium that can easily block the connector of the transmitter;

(4) When the tested medium solidifies or crystallizes due to changes in environmental temperature or process temperature;

(5) When replacing the tested medium requires flushing without mixing;

(6) When it is necessary to maintain sanitary conditions (pollution prevention).

1151GPThe remote pressure transmitter with the 1199 type still has various characteristics of the 1151GP type pressure transmitter.


1151GPtype

Pressure transmitter with remote transmission flange


code name

measurement range

4

5

6

7

8

0-6.22To 0-37.29kPa

0-31.1To 0-186.45kPa

0-117.21To 0-689.48kPa

0-0.345To 0-2.07kPa

0-1.172To 0-6.895kPa


code name

Output

E

4~20mA DC damping adjustable


code name

Pressure chamber; Plug-in ground; Isolation diaphragm

12

22

Cadmium plating on carbon steel

316SST

316SST

316SST

316SST

316SST


code name

Remote transmission flange

S1


S2

A remote transmission flange

Order according to Tables 5, 6, 7, 8, and 9

Two remote transmission flanges


code name

option

0Linear scale on-site indicator

0Square root scale on-site indicator (1151DP selected)

Bending bracket pipe installation (51mm pipe)

Bending bracket plate installation

Flat bracket pipe installation (? 51mm pipe)

M1

M2

B1

B2

B3




1151GP

6

E

12

S1

B1

Complete model of transmitter (typical)