Innovative technology in aging laboratory Aging laboratoryAlso known as an aging room (burning room), it is a high-temperature and harsh environment testing equipment designed to simulate high-performance electronic products (such as computer machines, displays, terminals, automotive electronic products, power supplies, motherboards, monitors, exchange chargers, etc.). It is an important experimental equipment to improve product stability and reliability, and an important production process for various manufacturing enterprises to improve product quality and competitiveness. This equipment is widely used in fields such as power electronics, computers, communications, and biopharmaceuticals. Configure the main system, main electrical system, control system, heating system, temperature control system, wind constant temperature system, time control system, test load, etc. according to different requirements. Through this testing program, defective products or parts can be detected, providing effective means for customers to quickly identify and solve problems, fully improving customer production efficiency and product quality.
Aging laboratoryControl System for Burner Room:
1. Controller: Color LCD display, touch screen input, can save the set values, sampling values, and sampling time of the experiment; The controller can simultaneously display and record the test curves of the set temperature and the measured temperature
2.485 USB interface: Equipped with a USB flash drive, the test program and test data can be transferred and stored through the USB flash drive, and then analyzed and managed on a PC.
3. Test holes: 2 with a diameter of 100mm
4. Operation method: Fixed value
5.Aging laboratoryThe controller has multiple sets of PID parameters, which can divide the entire temperature and humidity range into multiple sets of PID for control. It can achieve the best control effect within the temperature control range of the equipment, without the need for self-tuning or manual PID parameter adjustment for each temperature control point.
6. The control system adopts solid-state relay zero crossing triggering to reduce noise, minimize pollution, facilitate maintenance, and improve control accuracy.
7. In addition to the main controller, an independent overtemperature protector is also installed in the system. Even if the main controller fails, the overtemperature protector can reliably disconnect the heating power supply to protect the safety of the equipment and test samples.
8. Fault alarm function, self diagnosis function, fault handling prompt function, test timed operation stop function, box door opening prompt alarm
9. Aging laboratory equipment protection functions: adjustable over temperature protection, main power phase sequence and phase loss protection, power-off protection, leakage protection, overload and short circuit protection, main power voltage upper and lower limit alarm, etc
Aging laboratoryMain structure and configuration of the incinerator room:
1. Laboratory structure:
1). Adopting a modular storage board structure, it can be conveniently assembled at the buyer's site.
2). The indoor wall material of the laboratory is SUS304 stainless steel plate, and the outer wall material is cold-rolled steel plate. The outer surface is electrostatically painted with a light gray white color; The middle is a 100mm polyurethane foam and glass fiber cotton insulation layer.
3). The workshop floor is made of anti slip patterned steel plate, and the anti slip slope should ensure that the trolley can easily enter and exit the workshop. Install tracks according to customer requirements.
4). The laboratory adopts a double door structure, equipped with internal and external handles.
5). Explosion proof lighting fixtures are installed on the top of the workspace, with one cable outlet hole on each side (which can be sealed when not in use).
6)Aging laboratoryThe structure of the laboratory should be designed reasonably, manufactured with excellent technology, aesthetically pleasing both inside and outside surfaces, and the stainless steel plates and electrostatic spraying surfaces should be smooth and free of defects such as bumps and scratches.
2. The heater uses stainless steel 316L finned heat dissipation heating tube, which heats up quickly and has a long service life
3. The mixing system adopts a long axis fan motor and a stainless steel multi blade impeller that is resistant to high and low temperatures to achieve forced convection and vertical circulation, ensuring uniform and stable temperature inside the experimental chamber
4. The lead holes can be used for external testing of power or signal lines (the aperture or number of holes can be customized according to customer requirements)
5. The air duct is the main body for temperature regulation and circulation in the test chamber, made of stainless steel profiles cut by argon arc welding. The heating system and temperature circulation fan of this test chamber are used The temperature inlet and outlet are both installed in the air duct.