GC310 Fully Intelligent Wireless High Voltage Tester
Date: 2018-09-08Read: 12

GC310 Fully Intelligent Wireless High Voltage Tester

GC310 Fully Intelligent Wireless High Voltage TesterComposed of hook type voltage testers, telescopic insulation rods, receivers, etc., unlike traditional voltage testers that only test a single voltage level, fully intelligent voltage testing ranges from 1V to 550kV or higher voltage levels. When the bare wire voltage exceeds 60kV, non-contact electrical testing is used, and the tester gradually approaches the wire to complete the testing without touching the wire. For bare wires below 60kV, the voltage tester can be hung on the circuit for contact testing. Whether it is neutral wire, live wire, ground wire, high-voltage transmission line or metal conductor, as long as there is electricity, it may be direct transmission of electricity or leakage caused by insulation damage. The fully intelligent voltage tester can sense its electric field and emit a buzzing sound. The stronger the electric field near the wire, the more rapid the buzzing sound, warning that there is electricity.


The voltage tester can be hung on bare wires below 60kV for testing. It can be hung on wires or cables with a large outer diameter of 168mm, or on busbars with a large size of 168mm × 245mm, saving the operator's physical energy. The wireless high-voltage voltage tester has a straight-line receiving distance of about 160 meters, and the receiver adopts a 3.5-inch true color LCD screen with dynamic display, which is intuitive and clear. Insulated rods are lightweight, moisture resistant, high temperature resistant, impact resistant, highly insulated, and stretchable. Widely used in substations, power plants, fire departments, industrial and mining enterprises, as well as testing stations and electrical maintenance departments for electrical testing and field electrical operations.

Function

High voltage electrical testing, frequency testing, electric field judgment, etc

power supply

DC 3.7VRechargeable lithium battery, can work continuously for about 8-12 hours when fully charged

Electrical verification method

Contact type electrical testing: Bare wires below 60kV can be directly hung on the circuit for testing;

Non contact electrical testing: Non contact testing is used for lines above 60kV.

transmission method

433MHzwireless transmission

transmission distance

The straight-line distance is about 160m

display mode

3.5Inch true color LCD screen dynamic display

Hanging wire diameter

A 168mm wire or cable, or a 168mm × 245mm busbar

Scope of electrical testing

1V~550kV (50Hz/60Hz automatic)

Frequency: 45Hz~75Hz

Resolution

0.1Hz

Frequency accuracy

± 2Hz (voltage above 36V)

Induction intensity adjustment

When checking the electricity, press the left and right arrow keys to adjust the induction intensity of the electric field. The left arrow key weakens and the right arrow key strengthens, with several levels including 100V, 1000V, 10Kv, and 100Kv. It is suitable for places with dense power lines. When turned on, the default level is 100V with strong induction.

Insulation rod size

Approximately 5m in length after stretching; approximately 1m in length after shrinking (5 sections)

data storage

9999group

sampling rate

1~2 times/second

Instrument size

Hook type voltage tester: length, width, and thickness 310mm × 270mm × 52mm

Wireless receiver: length, width, and thickness 250mm x 100mm x 40mm

line voltage

60kVThe following bare wires can be directly contacted for testing; Bare wires above 60kV must undergo non-contact testing, and the voltage tester should gradually approach the tested wire.

data retention

Press the HOLD key to hold the data in test mode, and then press the HOLD key to cancel the hold

Exit function

Press the ESC key to exit the current function interface and return to the higher-level directory

Contact electrical testing

Contact voltage tester can only be hung in Zone A of hook type voltage tester

Data retrieval

After entering the data lookup mode, use the arrow keys to browse through the stored data

No signal indication

Dynamic display when the receiver does not receive the transmission signalThe words' No connection signal '

Auto Shutdown

After about 15 minutes of startup, the instrument panel automatically shuts down to reduce battery consumption

battery voltage

When the battery voltage is below 3.2V, the low battery voltage symbol is displayed to remind charging

Instrument quality

Hook type voltage tester: 486g (including battery)

Receiver: 1.45kg (including battery)

Total weight: 11.5kg (including insulation rod and battery)

Operating temperature and humidity

-10℃~40℃; Below 80% Rh

Storage temperature and humidity

-10℃~60℃; Below 70% Rh

Wireless interference

No interference from 433MHz same frequency signals

insulation strength

Insulation pole: AC 110kV/rms (after stretching all 5 insulation poles, between both ends)

Electrical tester: 2000V/rms (between the insulation rod connector and the top of the hook type detector)

Receiver: 2000V/rms (front and rear ends of the casing)

Structure

Anti drip type II

Hook type voltage tester

1Taiwan

wireless receiver

1Taiwan

antenna

2root

Telescopic insulating rod

1root

instrument box

1a

charger

1a

lithium battery

2Block (inside the instrument)

User manual/warranty card/certificate of conformity

1set