Shanghai Xiangqian Instrument SupplyMAXUM Edition II Process Gas Chromatography Analyzer2022019-001*,*Shanghai Xiangqian has a large inventory for a long time, *, *, *, inquire!
After decades of experience and technological development, MAXUM II process gas chromatography has become a leader in the industry in terms of performance, flexibility, and reliability.
MAXUM II is used in all branches of the fine chemical, refining, and hydrocarbon processing industries. Perform chemical composition analysis of gases and liquids in various production stages. MAXUM can be installed in harsh environments for direct online measurement, or installed near laboratories for continuous measurement. It is flexible in application and can analyze raw materials, process flow paths, final products, as well as process by-products containing waste and environmental hazards.
In addition, the MAXUM GC gas chromatography analyzer platform has added the option of modular column boxes. The modular column box is designed with an electric heating column box, which does not require instrument air. The entire chromatographic analysis module is integrated, and can be disassembled and replaced within a few minutes, greatly reducing the difficulty of operating and maintaining the gas chromatograph. Users can choose to repair the module on-site or send it back to Siemens factory for repair according to their personal convenience.
With the combination of different analytical components, MAXUM II provides a wide range of analytical possibilities. Therefore, only one product can accomplish measurement tasks of varying heights. This reduces the costs of investment, training, and components.
Details
Air bath column box/electric column box
detector type |
Thermal conductivity detector (TCD/8 units or 2 units), flame ionization detector (FID), flame photometric detector (FPD), helium ionization detector (HID), photometric ionization detector (PID), electron capture detector (ECD) |
Number of detectors |
Multiple selection of possible detector models |
Column box |
Single or double |
|
temperature range
|
Up to 280 ° C (electric column box); Up to 225 ° C (air bath) constant temperature column box |
Program temperature rise and below ambient temperature |
Up to~320 ° C (programmed heating), low to~20 ° C below ambient temperature (air bath column box) |
Sample valve |
Gas or liquid (multiple valve options available) |
Modular box
Detector type: Thermal conductivity detector (small module with 4 channels, large module with 2x4 channels) |
Multiple selection of possible detector models based on the number of detectors |
Column box single or double, each with a large or small column box, optional |
Temperature range 60-80 ° C |
|
Program heating and---
Below ambient temperature
degree
|
Sample/Valve Gas Sample, M 50 Valve |
feature
Multiple detector configurations, including FID, TCD, FPD, PDD (in HID, PID, or ECD modes)
Intelligent electronic, local operation, central workstation for fast, simple operation, maintenance, and monitoring
2017799-001 Discontinued. Replaced with 2022019-001.
No longer in use, replaced by 2022019-001
2021828-001 Power Entry and Control Module (PECM-2) (Electronics only).
Power Input and Control Module (PECM-2) (Electronic only)
Maxum I or II
Maxum I or II
2022019-001 Power Entry Ctrl Mod. (PECM-2) with Temperature & SVCM Control
(complete replacement kit).
Power input and control module (PECM-2) with temperature control and SVCM control (complete)
Replacement spare parts package)