Ultrasonic level gaugeIt has broad application prospects in the chemical industry, and its non-contact measurement, high precision, and strong adaptability can meet the high requirements for liquid level measurement in chemical production. Proper selection, installation, and maintenance are key to ensuring its stable operation. The common problems and solutions encountered in the application of chemical industry are as follows:
Foam or suspended solids interference
Problem: foam or suspended solids may cause measurement errors.
Solution: Choose an ultrasonic level gauge with strong anti-interference ability or install a waveguide.
High temperature medium influence
Problem: High temperatures may cause sensor damage or inaccurate measurements.
Solution: Choose a high-temperature resistant model and ensure a safe distance between the sensor and the medium.
signal attenuation
Problem: In large storage tanks, signal attenuation may lead to inaccurate measurements.
Solution: Choose a high-power ultrasonic level gauge or add a signal amplifier.