6I, Building B (Office), Central Avenue, Intersection of Xixiang Avenue and Baoyuan Road, Labor Community, Xixiang Street, Bao'an District, Shenzhen City
User Voice | INFICON EcoBoost: Accurate acceleration for helium/hydrogen leak detection, helping to reduce costs and increase efficiency
Date: 2025-11-21Read: 4
User Voice | INFICON EcoBoost: Accurate acceleration for helium/hydrogen leak detection, helping to reduce costs and increase efficiency
Manchester, EnglandVacuum Engineering Services Company (VES)Having over 30 years of experience in the field of industrial leak detectionRich experience and renowned for reliability. As a long-term partner of INFICON, VES is involved in the LDS3000leak detectorThe breakthrough firmware feature EcoBoost played a key role in the beta testing.
INFICON EcoBoost technology can dynamically predict and compensate for background interference of test gases during the measurement process.Whether using helium or hydrogen astracer gasCan do it allSignificantly improve the speed, efficiency, and cost-effectiveness of leak detection.
Thirty years of professional accumulation in leak detection
Since its establishment in 1994, VES hasDeliver over 1600 leak detection systems worldwideOur service areas cover multiple industries such as automotive, energy, and electronics. Its business includes:
Design and Manufacturing of Detection System
Global Service and Technical Support
Training, consulting, and equipment upgrades
Internal and on-site leak detection services
Helium Recovery and Purification Solution
VES has technology centers in the United States, Mexico, the United Kingdom, the Czech Republic, and China, closely integrating its global service network with strong engineering capabilities.
The key role of dynamic background compensation
On the production line, leak testing must strike a balance between speed, cost, and quality.Traditional static background compensationSimilar to the "peeling" function of a scale: only measure the residual background value once after vacuuming the vacuum chamber. However, this methodThere are two major shortcomings:
1.Need to wait for the vacuum pumping process to stabilize;
2.If the measurement is started too early, small leaks may be ignored, while larger leaks may be misjudged.
EcoBoost technology effectively solves the above problems by dynamically predicting background gas changes and subtracting them from measured values in real time, thereby achieving:
Shorter testing cycleMore reliable detection of minor leaksLower helium consumption
Click on the video to view a detailed introduction to EcoBoost
User Voice | INFICON EcoBoost: Accurate acceleration for helium/hydrogen leak detection, helping to reduce costs and increase efficiency
Original, Voice of Users | INFICON EcoBoost: Accurate acceleration for helium/hydrogen leak detection, helping to reduce costs and increase efficiencyINFICONSynchronized to take a lookWrite your comment
Hydrogen has significant cost advantages, but its application in vacuum chambers is difficult due to strong background interference. INFICON has optimized EcoBoost to continuously compensate for hydrogen background,Shouci turns hydrogen leak testing into reality.
VES shouxi engineer Andrea Whittle is working onFuel cell vehiclesEcoBoost was tested in the application of hydrogen composite storage tanks, and the following conclusions were drawn:
Andrea WhittleVES company shouxi engineer
When EcoBoost is not turned on, the fluctuation range of hydrogen leakage rate measurement within one hour is 10% to 20%; After enabling EcoBoost,The fluctuation range has decreased to only 2% to 5%The reproducibility has significantly improved.
The EcoBoost system has achieved the expected results. It makes leak detection faster, more efficient, and more economical. ”
Faster helium detection in automotive applications
VES also applies EcoBoost technology to helium leak detection in motorcycle and agricultural fuel tanks.When multiple fuel tank models are involved in the same production line, EcoBoost ensures that the detection process is not interrupted - even if a leak is detected, the LDS3000 can automatically compensate without waiting for the detection room to clear, thus maintaining the detection rhythm and avoiding downtime.
Carbon fiber storage tank testing
Reduce helium concentration without sacrificing detection speed
EcoBoost technology supports testing with lower concentrations of helium gas.In HVAC/R applications,Some customers have requested to use only 10% helium for testingUsually, this will result in longer vacuuming time and slower testing cycles. However, with the help of EcoBoost, the testing speed was maintained while the helium consumption was significantly reduced.
Significant industry advantages
For VES and its customers, EcoBoost technology brings the benefits of quanfangwei:
Shorter testing cycle More stable and reliable test resultsLower tracer gas consumptionShouci implements practical hydrogen testing
With EcoBoost technology, INFICON and VES are continuously expanding the boundaries of industrial leak detection, creating quantifiable value for multiple industries such as automotive, new energy, and refrigeration.