Laser coding smoke exhaust fan deodorization purifier
Smoke Purifier with Laser Marking and Carving for Smoking and Odor Removal: The laser smoke and dust purifier is independently developed and produced by Weinan Technology. It is a professional equipment for targeted treatment of dust, smoke, odor, exhaust gas and other related industries such as laser marking, laser engraving, laser coding, laser spraying, laser welding, laser beauty, laser cutting, etc.
Product Application
Laser smoke, dust, and odor treatment:
1. Laser marking and vacuum cleaning equipment (suitable for precious metal marking and recycling, plastic laser vacuum cleaning and deodorization)
2. Laser cutting of acrylic PVC、 Deodorization and smoke removal of materials such as rubber and leather (suitable for advertising board processing industry, clothing processing industry, mobile phone case processing industry...)
3. Medical beauty, moxibustion, health preservation, smoke and odor removal (suitable for laser mole removal, spot removal, wrinkle removal, laser micro carving, moxibustion health center...)
4. Laser engraving for smoke, odor, and deodorization (suitable for rubber plate making industry, laser engraving industry...)
*Smoke filtering integrated structure design, easy installation, flexible movement, no need to lay smoking pipes.
*High power DC brushless motor, long lifespan, low noise, and generates high air flow.
User Notice
settings key
When the machine enters the alarm state and the buzzer sounds, you can press this button once to cancel the buzzer sound. Pressing this key before entering the alarm mode will query the cumulative running time of the entire machine.
Panel lock key
Pressing this button while the machine is in operation will lock all function keys on the control panel of the machine out of operation. Press this button again or disconnect the power supply of the entire machine and restart it before releasing it.
Possible reasons: ① Blocked air inlet or outlet
② The filter element reaches saturation and fails, resulting in blockage
Solution: Turn off the power, open the top cover, and check if there are any foreign objects blocking the air vent; Check if the air outlet is blocked again.
If there are no abnormalities after inspection and handling, restart the machine. If the air volume is still low, replace the filter element.
2. Fault phenomenon: The machine automatically shuts down immediately after starting, and then restarts and repeats the above phenomenon.
Possible reasons: Internal airflow obstruction, excessive resistance of the filter element, resulting in excessive starting current of the fan, and automatic protection shutdown of the system.
Solution: Turn off the power, open the top cover, and check if there are any foreign objects blocking the air vent; If there are no abnormalities found during inspection and processing, turn down the air volume knob, then restart the machine and adjust the knob to the appropriate air volume position.
3. Fault phenomenon: The equipment is not working.
Possible reasons: ① The power switch on the back of the machine is not turned on
② The fuse inside the three in one switch has blown
③ The knob on the control panel is not turned clockwise