Introduction to MS600 Toxic and Harmful Gas Detector:
The MS600 portable toxic and harmful gas detection alarm is used for portable and rapid detection of toxic and harmful gas concentration, temperature and humidity measurement, and alarm for exceeding the standard. Adopting a 2.5-inch high-definition color screen for real-time display of concentration, imported brands (Honeywell, Nippon Genshin, CITY, Alpha, Dynament, Membrapor, etc.) gas sensors are selected. The main detection principles include electrochemistry, infrared, catalytic combustion, thermal conductivity, and PID photoionization. Advanced circuit design and mature kernel algorithm processing. MS600 can detect gas concentrations in pipelines, confined spaces, and atmospheric environments. It can detect gas leaks or high concentration single gas purities with various background gases such as nitrogen or oxygen, and can detect over 500 types of gases.

Characteristics of MS600 Toxic and Harmful Gas Detector:
Waterproof, dustproof, explosion-proof, shockproof, intrinsically safe circuit design, anti-static, anti electromagnetic interference, passed national standard testing and CPA type certification for measuring instruments
Protection level IP67, can withstand rain and short-term immersion, built-in replaceable water vapor and dust filters, can be used in high humidity and high dust environments without damaging sensors and instruments
Built in pump suction measurement, fast response, sampling distance of more than 10 meters, special gas path design, optional accessories can detect negative or positive pressure of -0.5 to 2 kilograms of gas, without affecting the measurement results
The high-definition 2.5-inch color screen displays real-time information such as concentration, alarm, time, temperature, humidity, storage, communication, printing, battery level, charging status, etc. The menu interface uses high-definition simulation icons to display the function names of each menu
● Large capacity data storage function, customizable for larger capacities. Optional SD card storage function, supporting real-time storage, timed storage, or only storing alarm concentration data and time, supporting local viewing and deletion of data, and can also upload data to the computer through USB, infrared communication, RS232 interface, and use upper computer software to analyze, store, and print data. Support remote wireless transmission (optional function)
● Infrared communication interface (optional), USB interface, RS232 interface automatic recognition, optional external micro wireless infrared printer, printing: company name, gas name, date and time, environmental temperature and humidity, concentration data, test results (whether qualified)
● USB charging interface, can be charged with a computer or power bank, compatible with mobile phone chargers, overcharge, overdischarge, overvoltage, short circuit, overheating protection, 5-level accurate power display, supports USB hot plugging, and the detector can work normally during charging
Adopting a 6000mAh high-capacity rechargeable polymer battery, it can work continuously for a long time
Sound and light alarm, vibration alarm, visual alarm, undervoltage alarm, fault alarm, and multi-directional stereoscopic display of alarm status during alarm.
The alarm value can be set, and the alarm methods can be selected from low alarm, high alarm, interval alarm, and weighted average alarm
High precision temperature and humidity measurement (optional), with temperature compensation for the sensor. The instrument operates within a temperature range of -40 to 70 degrees and can detect gases up to 1300 degrees Celsius (optional high temperature sampling, cooling, and filtering handle or high temperature and high humidity pretreatment system)
It can detect in real-time or at regular intervals (for situations where the amount of gas being measured is relatively small), and the pump can be turned off to extend the start-up time when not detected.
● It can be selected to simultaneously detect 1-6 types of gases, up to 8 types of gases, and the units can be freely switched. Conventional gases do not require input of molecular weight, while special gases require input of molecular weight to automatically calculate and switch. Units can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/L
Three display modes can be switched: simultaneously displaying four gas concentrations, large font cyclic display of single channel gas concentration, real-time curve, automatic or manual cycling between channels can be switched, whether to display maximum value, minimum value, gas name can be set, and historical record curve graphs can be viewed.
The interface can be switched between Chinese and English, with a default Chinese interface and concise Chinese or English operation prompts. Users of all ages can easily operate it
● Data recovery function, which can be selectively restored or fully restored. Automatic identification and prevention of concentration calibration errors to avoid adverse effects caused by human factors.
● Zero point automatic tracking, multi-level calibration of target points to ensure measurement linearity and accuracy. Can simultaneously comply with national standards and local metrology bureau standards
● It can record calibration logs, maintenance logs, troubleshooting solutions, remind sensor life expiration, and remind the next concentration calibration time
Technical parameters of MS600 toxic and harmful gas detector:
gas detection |
Toxic gases, oxygen, carbon dioxide, flammable and explosive gases, TVOC, etc., 1-6 gases can be freely combined. Can be expanded to 8 types of gases, depending on the sensor, optional: temperature and humidity measurement. |
||||
Application scenarios |
All occasions that require portable and rapid detection of gas concentration, such as petroleum, chemical, pharmaceutical, environmental protection, gas distribution, warehousing, flue gas analysis, air treatment, etc. |
||||
Testing Scope |
0~1、10、100、1000、5000、50000、100000ppm、 200 milligrams per liter 100% LEL, 20%, 50%, 99.999%, 100% Vol are optional, and other ranges can be customized. |
||||
resolution |
0.01ppm or 0.001ppm (0-10ppm), 0.01ppm(0~100 ppm), 0.1ppm(0~1000 ppm), 1 ppm (0-1000 ppm or more), 0.01 milligrams per liter (0-200% milligrams per liter), 0.1%LEL, 0.01%, 0.001%Vol |
||||
Detection Principle |
Electrochemistry, catalytic combustion, infrared, thermal conductivity, PID photoionization, etc., depending on the gas type It depends on the measurement range, on-site environment, and user requirements. |
||||
allowable error |
≤± 1% F.S (other accuracies can be customized) |
||||
Linearity |
≤±1% |
Repeatability |
≤±1% |
uncertainty |
≤±1% |
response time |
T90 ≤ 20 seconds |
recovery time |
≤ 30 seconds |
||
working environment |
Temperature: -40 ℃~+70 ℃, humidity: ≤ 10~95% RH, built-in filter can be used in high humidity or high dust environments |
||||
Sample gas temperature |
-40 ℃~+70 ℃, equipped with a high-temperature sampling and cooling filter handle, capable of detecting smoke concentration at 1300 degrees Celsius |
||||
Temperature and humidity measurement |
Optional: Temperature -40 ℃~+70 ℃, accuracy 0.5 ℃; Humidity 0-100% RH, accuracy 3% RH |
||||
working power supply |
3.7VDC, 6000mAh high-capacity rechargeable polymer battery |
||||
display mode |
2.5-inch high-definition color screen |
||||
Detection method |
Built in pump suction measurement with a flow rate of 500 milliliters per minute. The calibrated flow rate should be greater than 500 milliliters per minute, and a three-way pipe should be connected for diversion to ensure that excess gas is discharged from the bypass |
||||
alarm method |
Sound and light alarm, vibration alarm, sound and light+vibration alarm, and alarm shutdown can be set |
||||
Alarm Volume |
90-120 decibels. |
||||
communication interface |
USB (charging and communication), optional: RS232, infrared communication, automatic recognition |
||||
data storage |
Comes standard with large capacity data storage and supports expansion. |
||||
Protection level |
IP67 |
||||
Explosion proof type |
intrinsically safe |
||||
Explosion-proof marking |
Ex ia IIC T4 Ga |
||||
execution standard |
GB 15322.3-2019 "Portable Combustible Gas Sensors with Measurement Range of 0-100% LEL" GB 3836.1-2010 General Requirements for Electrical Equipment Used in Explosive Gas Environments GB 3836.4-2010 "Inherent Safety Type 'i' of Electrical Equipment for Explosive Gas Environments" |
||||
Overall dimensions |
195×77×46mm(L×W×H) |
||||
weight |
350g (slightly different for different gas combinations) |
||||
Standard Appendix |
Instruction manual, certificate of conformity, warranty card, USB charger (including data cable), high-end aluminum alloy instrument box, back clip, humidity dust filter |
||||
Optional items |
Temperature and humidity measurement function, 1.2m extendable sampling handle (1-10 meter hose, standard length 1 meter), 0.4m stainless steel sampling handle (with dust filter, non extendable), high temperature sampling and cooling filter handle, high temperature and high humidity pretreatment system, multiple humidity and dust filters, hanging rope, CD (upper computer communication software), SD card storage, wireless data communication, external micro wireless Bluetooth printer |
||||