Product Name: In situ Laser Process Gas Analyzer

Product model: GasTDL-3100

The GasTDL-3100 in-situ laser process gas analyzer is a high-performance optical analysis instrument based on tunable semiconductor laser absorption spectroscopy (TDLAS) technology. It adopts a collimated design and can be used for industrial process gas control; Its response time is fast, usually calculated in seconds in in-situ measurement, avoiding the time delay caused by sampling measurement, and can timely reflect the measured gas concentration online.

Product characteristics of in-situ laser process gas analyzer:

1. Using TDLAS technology, the measured gas is not affected by background gas interference

2. In situ installation, no need for sampling preprocessing system

3. Fast response (T90 ≤ 4s), capable of real-time reflection of gas concentration

4. Real time online measurement, gas concentration not easily distorted, high measurement accuracy

5. Has good adaptability in harsh measurement environments such as high temperature, high dust, high moisture, high corrosiveness, and high flow rate

6. Explosion proof design with high safety factor

7. Simple construction, no movable components, no loss components, maintenance free

Technical parameters of in-situ laser process gas analyzer:

Performance parameters of in-situ laser process gas analyzer

Measuring components

O2、CO、CO2、CH4*

Measuring principle

TDLAS

test scope

O2: (0-5)% VOL (customizable 100 '%)

CO:(0 ~ 100)%VOL

CO2:(0 ~ 100)%VOL

CH4:(0 ~ 20)%VOL

precision

≤±1%F.S.

repetitiveness

≤±1%F.S.

range drift

≤±1%F.S.

resolution

0.01%VOL

response time

T90≤1s

working parameters

Explosion-proof rating

Exd II CT6

Installation method

In situ installation

ambient temperature

(-20~ +60)℃

working power supply

24V DC,24W

Blow off gas

(0.3-0.8) MPa industrial nitrogen

Interface signal

communication

RS485、RS232

output mode

2-channel 4-20mA output

3-channel relay output

*Note: Each analyzer measures the concentration of a single component gas


Measurable: O2, CO, CO2, CH4 * gas components

*Note: Each analyzer measures the concentration of a single component gas.