Brief Introduction

rated voltage0.66/1.14KV and mining mobile rubber sheathed flexible cable (GB12972.5-91)

This product is suitable for rated voltageCopper core rubber sheathed flexible cable for mobile equipment of 0.66/1.14KV and below

model

name

main purpose

MY)UY-0.38/0.66

Mining mobile rubber sheathed flexible cable

The rated voltage is0.38/0.66KV power connection for various underground mobile coal mining equipment

(MYP)UYP-0.38/0.66

Mining mobile shielded rubber sheathed flexible cable

The rated voltage is0.38/0.66KV power connection for various underground mobile coal mining equipment

(MYP)UYP-0.66/1.14

Mining mobile shielded rubber soft sheathed cable

The rated voltage is0.66/1.14KV power connection for various underground mobile coal mining equipment

core countX conductor


Nominal thickness of sheath(mm)

outer diameter of cable

Reference weight of cable(kg/km)

Nominal cross-section(mm2)

Power cord core

UC-0.38/0.66

UCP-0.38/0.66


Power cord core

Ground wire core

Insulation Thickness(mm)

Small value

Large value

Small value

Large value

UC

UCP




3×4

1×4

1.4

3.5

20.3

23.4

23.7

27.2

670

785



3×6

1×6

1.4

3.5

23

26.4

26.4

30.1

838

927



3×10

1×10

1.6

4

27.5

31.3

30.9

34.7

1292

1400



3×16

1×10

1.6

4

29.6

33.4

33

36.8

1465

1586



3×25

1×16

1.8

4.5

35.6

39.8

39

43.2

2159

2296



3×35

1×16

1.8

4.5

38.7

42.1

42.1

46.3

2596

2783



3×50

1×16

2

5

43.6

47.1

47.1

51.4

3385

3548



3×70

1×25

2

5

49.7

54.4

52.4

57.1

4292

4477



core countX conductor



outer diameter of cable

Reference weight of cable(kg/km)

Nominal cross-section(mm2)

Power cord core

Sheath nominal

UC-0.38/0.66

Power cord core

Ground wire core

Insulation Thickness(mm)

thickness(mm)

Small value

Large value

3×10

1×10

1.8

4.5

32.4

36.2

1476

3×16

1×10

1.8

4.5

34.6

38.4

1737

3×25

1×16

2

5

41.4

45.3

2400

3×35

1×16

2

5

44.2

48.4

2857

×350

1×16

2.2

5.5

49.1

53.4

3549

3×70

1×25

2.2

5.5

55.5

60.2

4608

3×95

1×25

2.4

6

61.2

65.9

4608

Insulation resistance between cable insulation main cores and between main cores and ground wireWhen converted to+20 ℃, it should not be less than 100M Ω· km.

Convert the transition resistance of the main core shielding layer toNot exceeding 3k Ω at 20 ℃.

Product standard:MT818.5-1999。

The MYP cable consists of three main cores with insulation shielding and a ground wire wrapped in a semi conductive rubber layer, which is twisted around the semi conductive rubber layer to form a cable. Squeeze black chlorinated polyethylene rubber sheath or black chloroprene rubber sheath outside. Conductive core: Made of soft copper wire, its performance complies with GB/T3956-1997. Insulation: XJ-00A rubber according to GB7594.2-1987 is used. Core identification: Insulation color separation identification is used, with the main core being red, green, and white. Ground wire: covered with a semi conductive rubber. Insulation shielding: Cover the insulation surface with a semi conductive tape. Cabling: Three main cores and one ground wire are twisted in the right direction around a semi conductive rubber pad core to form a cable. Sheath: XH-03A rubber according to GB7594.7-1987 is used. The oxygen index of the sheath rubber is ≥ 40. The flame retardant performance of the finished cable meets the requirements of MT386-1995. Cable marking: The surface of the cable is printed with the model, voltage, specifications, and manufacturer's name.