The Runda Zhongke TRD-M2000 differential pressure gauge is suitable for measuring micro pressure differences in air. It can be installed on the outside of the clean room wall in an embedded or suspended manner, without the need for a power supply. It has high sensitivity and is an ultra-low range, inexpensive, and structurally strong on-site indicator instrument that can quickly indicate the pressure of low-pressure, non corrosive gases.
Mainly suitable for dust collectors, differential pressure control of air shower rooms in purification rooms, display of air pressure at fire staircase vents, pharmaceutical GMP certification, measurement of pressure difference in high, medium, and high efficiency filters, monitoring of differential pressure at air conditioning inlet and outlet, control of air to gas ratio and automatic valve control during combustion, and monitoring of blood pressure and respiratory pressure in medical and healthcare equipment.
Usage and selection of differential pressure gauge
1.Installation: Select the appropriate installation location based on the model and specifications of the differential pressure gauge. Ensure that any factors that may cause measurement errors are avoided during the installation process.
2.Calibration: Before use, the differential pressure gauge should be calibrated to ensure the accuracy of the measurement results.
3.Usage: Regularly check the reading of the differential pressure gauge, record and analyze the data. If any abnormal situation is found, timely measures should be taken to handle it.
4.Maintenance: Regularly clean and maintain the differential pressure gauge to ensure its long-term stable operation. If you need to replace parts or perform repairs, please contact a professional for assistance.
When choosing a differential pressure gauge, multiple factors need to be considered. Purification room differential pressure gauge, circular differential pressure gauge, and pointer differential pressure gauge each have their own characteristics, and should be selected according to specific application scenarios and needs. For example, in situations where remote monitoring is required, a differential pressure gauge with digital output function can be selected; In situations where high display accuracy is required, pointer or digital high-precision differential pressure gauges can be chosen.