VEGAPULS 6X is a universal continuous level measuring instrument that can measure the level of all liquid and solid media under any process conditions. With practical application oriented instrument configuration and debugging, VEGAPULS 6X provides accurate, reliable, and cost-effective solutions for various level measurement applications. Through various types of antenna systems, VEGAPULS 6X can achieve maintenance free operation in various applications.

Technical Specifications
Range Distance
  • 120 m [Meter - Foot]

Process temperature
  • -196 . .. 450 °C [°C - °F]

Process pressure
  • -1 . .. 160 bar [Bar - kPa - psi]

measurement accuracy
  • ± 1 mm

frequency
  • 6 GHz

  • 26 GHz

  • 80 GHz

Launch angle
  • ≥ 3°

Contact medium material
  • PTFE

  • PVDF

  • 316L

  • PP

  • PEEK

threaded connection
  • ≥ G¾, ≥ ¾ NPT

flange connection
  • ≥ DN20, ≥ ¾'

Sanitary Connection
  • 卡箍 ≥ 1 ½' - DIN32676, ISO2852

  • Threaded pipe joint ≥ 2 ', DN50- DIN 11851

  • Varivent ≥ DN25

  • Sanitary flange pressure plate connection - DN32

  • Sanitary round nut connection - F40

  • Sanitary threaded joint ≥ DN50 pipe diameter ø 53- DIN11864-1-A

  • Sanitary flange connection ≥ DN50- DIN11864-2

  • Sanitary clamp ≥ DN50 pipe diameter ø 53- DIN11864-3-A

  • DRD connection ø 65 mm

  • SMS 1145 DN51

sealing material
  • EPDM

  • FKM

  • FFKM

  • Graphite and ceramics

  • PTFE

housing material
  • plastic

  • aluminium

  • Stainless steel (precision castings)

  • Stainless steel (electrolytic polishing)

Protection level
  • IP66/IP68 (0.2 bar)

  • IP66/IP67

  • IP66/IP68 (1 bar)

  • IP69K

output
  • Profibus PA

  • Two wire system: 4... 20 mA/HART

  • Modbus

  • Four wire system: 4-20 mA/HART

  • Ethernet APL

ambient temperature
  • -40 . .. 80 °C