Parameter setting method for HZD-B-X digital vibration transmitter to meet different equipment vibration monitoring needs
1、 Set parameters
HZD-B-XThe vibration protection transmitter has already adjusted and calibrated various parameters before leaving the factory. Just connect the corresponding cables, usually without any adjustment or verification. butHZD-B-XThe protective transmitter also provides you with complete adjustment functions, including adjustable parameters such as two-level alarm points, zero point of vibration output, and full-scale calibration. openHZD-B-XTo protect the label of the transmitter, you can adjust the size of the two-level alarm points,4-20mAYou can also verify the full range of the instrument based on the zero point output. Equipped with multi-channel protection devices and flexible and diverse options, it enablesHZD-B-XProtect the transmitter to tailor it to your needs.
HZD-B-XThe vibration transmitter can choose its function according to various on-site requirements and ordering options.HZD-B-XThe transmitter can output4-20mAThe total vibration value, two-level alarm, buffering output of the original signal, can choose acceleration, velocity, displacement and other values for the total vibration value, and has different full-scale options for selection.
3、 Measurement parameters
The split vibration transmitter is paired with a vibration velocity sensor to measure the absolute vibration of rotating mechanical bearings and output current signals. It can be used with computersDCSThePLCsystem,Connect devices such as paperless recorders.
Fault monitoring: Monitor the absolute vibration of rotating machinery, such as casing vibration, bearing vibration, frame vibration, etc; Monitor the increase in vibration caused by rotor imbalance, misalignment, loose components, damaged rolling bearings, gear damage, etc.
Measurement parameters: displacement, velocity.
Unit type: Monitoring of vibration in small and medium-sized units, such as steam turbines, fans, compressors, motors, pumps, gearboxes, etc; Especially suitable for the renovation of old units.
Installation requirements: Only one screw hole needs to be drilled on the casing to fix the sensor on the double headed screw, without any operation inside the machine.

4、 Installation method
Fix the sensor at the measurement position of the device, install the transmitter on the guide rail of the control cabinet, and connect the two signal wires of the sensor to the transmitter respectivelySignalof+”End“-”End (magnetic electric vibration velocity of two lines is not positive or negative). transmit4-20mASignal connection toDCS/PLCSystem.POWER(+)Connect the positive pole of the power supply,POWER(-)Connect the negative pole of the power supply. After the connection is made and checked for accuracy, power can be turned on. Installation of guide rails or base plates.