During the painting operation in the paint mixing room, toluene and xylene gas will be volatilized, and toluene is a flammable gas. When the concentration of toluene reaches a certain value, accidents are prone to occur. The HRP-T1000 toluene gas concentration leak alarm for paint mixing room is a gas detection instrument used to detect the specific concentration of toluene and xylene. It uses imported sensors and has high detection accuracy.

General parameters:

Detection principle: infrared

1. Working principle: diffusion type

2. Electrical interface: Left G1/2, Right M20 * 1.5

3. Explosion proof rating: Ex d IIC T6 Gb

4. Protection level: IP65

5. Output signal: 4-20mA three wire system/RS485 four wire system or two-wire system

6. Power supply voltage: DC24V

7. Power consumption:<5W

8. Accuracy: ± 3% F.S

9. Output indicator: digital display/LCD display/no display

10. Humidity: 0-95% RH

11. Response time: T90 ≤ 30s

12. Switching signal: 1 (default passive output)

13. Monitor: DCS, PLC

14. Exterior dimensions: 210mm * 190mm * 95mm

15. Weight: 1.2kg

Power: 3kw