Shanghai Yichuan Turbine Flow MeterWidely applicable, conducting industrial furnace heat balance testing [8] is undoubtedly of great economic benefits for mastering the thermal energy utilization of industrial furnaces, improving product quality, saving energy and reducing costs for enterprises. In the actual testing process, turbine flowmeter is the first choice in industrial boiler thermal balance testing due to its high accuracy, wide measurement range, high pressure resistance, and digital signal output.
In the actual situation of industrial boilers, due to various constraints, the water supply of industrial boilers is generally an intermittent water supply method that varies with time load. This method determines the flow of fluid in the main pipeline of the boiler water supply, that is, the flow of water supply is usually characterized by turbulent flow, that is, the water flow in the pipeline of industrial boilers is irregular and mixed with each other while flowing. Accurately measuring the water supply flow rate and temperature of industrial boilers is crucial for correctly analyzing the results of thermal balance tests. Turbine flow meters can accurately and timely respond to turbulent changes in water flow precisely because they have digital signal output and corresponding sensitivity. Within a time period, the flow rate of the water supply pipeline of an industrial boiler is the integral of the pipeline cross-sectional area F, that is, Q=∫ FVDF, while other principle flow meters are difficult to achieve the high accuracy of turbine flow meters.