1、 Throughout the application process, it is essential to ensure that the liquid level gauge is vertical. If there is a tilt, it will cause friction between the magnetic float components and the precise measuring tube cavity, resulting in damage to the components and endangering the actual application effect, and may lead to data errors.
2、 In the case of installing and connecting the safety channel in the design scheme, it is good to retrofit a pair of shut-off valves between the magnetic flap level gauge and the installation socket. This pair of gate valves may seem to increase the cost by a small amount, but their effectiveness is indeed very significant. It facilitates future maintenance, upkeep, cleaning, and repair, and can also be safely and conveniently disassembled and replaced in case of common malfunctions in the level gauge.
3、 Various situations are likely to occur throughout the entire process of industrial production. Due to the principle of the magnetic flap level gauge, attention should be paid in production and manufacturing. It is not necessary to stack household appliances or raw materials containing magnetism around the level gauge, which will immediately cause inaccurate measurement data information. In more serious cases, it will continue to damage the magnetic components inside, making it impossible for it to be used normally.
4、 After each cleaning of the internal part of the magnetic flap level gauge, pay attention to slowly injecting the liquid in the measured vessel into the precise measuring tube. Excessive water flow can cause impact on the water pump pressure switch, and in severe cases, it can damage the water pump pressure switch, resulting in the inability to accurately measure the level gauge.
5、 When the measured medium has a settling condition, it is necessary to carry out sewage treatment and cleaning of the magnetic flip hook liquid meter on time and at regular intervals. Excessive precipitation can cause deviation in accurate measurement data information and reduce the service life of the liquid level gauge.
6、 Practical operators should closely monitor whether there is any liquid leakage in their daily applications, and immediately replace the components that have leaked to avoid exposing the medium and causing corrosion and damage to the liquid level gauge.
7、 At the beginning of the design of the magnetic flap level gauge, it is necessary to present the appropriate flange specifications and specifications. If the hole is not yet opened on site and the manufacturer must match the flange, then only the flange size specifications must be presented.
8、 If the flange opening under the tank is close to the bottom of the tank on the spot, and there is no distance between the tank and the inside, then it is suggested not to rush to open the hole on the spot. Wait for the liquid level gauge to arrive on the spot before opening the hole. In such cases, the flange opening below generally needs to be 30CM away from the bottom of the tank. Unless there is no need to bring a filter valve on the spot, or if the filter valve is made with an angled side outlet, it can reduce the distance between the opening of the method blue and the bottom of the tank by about 15-20 centimeters. Due to the length of the float and the filter valve, as well as the thickness of the two flanges, starting from the zero scale downwards, it is suggested to build a concrete service platform with a height to width ratio of 15-30 centimeters at the bottom of the pottery jar, otherwise there will be a bottom cultivation area. People who have had on-site work experience will understand this point.
9、 If the magnetic flap level gauge with remote transmission is installed on an outdoor tank, it is proposed to carry out moisture-proof maintenance on the head of the remote intelligent transmitter.
10、 Around the magnetic flap level gauge, it is also not allowed for chemical substances containing conduction band magnetism to come close. When bundling the remote type magnetic flap level gauge, it is important to note that it is strictly prohibited to use iron materials to reinforce the bundling structure, as this may result in the level gauge not functioning properly.
11、 When encountering common faults, do not solve them on your own without prior preparation. It is important to understand the reasons before conducting comprehensive repairs. If there are any unclear situations, you can consult with the manufacturer. Otherwise, damaging the components of the liquid level gauge will result in significant losses.
12、 Before application, the calibration magnetic tile should be used to set the spheres below the zero position of the liquid level gauge in bright red, and the spheres in other positions in milky white.
13、 In the case of customers independently adding heat tracing pipelines, non magnetic raw materials such as copper pipes should be selected, and the temperature of the heat tracing pipelines should be determined based on the actual medium. The installation location of the magnetic flap level gauge should also pay attention to avoiding or eliminating the import and export trade of the medium, otherwise it may endanger the accuracy of the precise measurement data information due to the rapid change of the medium in some areas. Another important thing to note about the magnetic flap level gauge is that there does not need to be any solid residue in the medium, which means it contains magnetic chemicals that can obstruct the operation of the water pump pressure switch.