On October 12, single, double flange capillary differential pressure transmitter, measuring range 0~120KPa, DN50, material 304, flange grade PN63, M side, diaphragm material, 316L+gold plating, capillary double 3.5m, because the medium contains hydrogen, gold plating diaphragm is selected.
Double flange capillary differential pressure transmitter

On October 12th, a single flange liquid level transmitter, DN80, Flange material: 304316L diaphragm, single capillary tube length of 5m, range of 0~3525mmH2O, axial installation, 1 set.
Direct installation diaphragm pressure transmitter, DN25, PN40316L diaphragm, with a range of -0.1~1.0MPa and 0~1.6MPa, totaling 2 units
Single flange liquid level transmitter

Direct installation diaphragm pressure transmitter

On October 16th, two pressure transmitters with M20 * 1.5 threaded interface and a range of -0.1~0.6MPa were installed directly.
Double flange differential pressure level transmitter, with a range of 0-4m, DN50, tantalum diaphragm, capillary length H=3.5m, L=4.5m, convenient for placing the transmitter body under the lower flange to extend its service life, radial installation, 1 set.
Direct installation pressure transmitter

Double flange differential pressure level transmitter

On October 18th, one DN25316L diaphragm pressure transmitter with a range of 0-4.0MPa was installed directly
Double flange differential pressure level transmitter, with a range of 0~3500mm, DN50, titanium diaphragm. Due to the high storage tank on site, a double 7m capillary tube was used for easy observation, which caused a problem. The range is small and the capillary tube is long, so a capacitive type was used. Due to the large compression ratio of the range, stability and linearity were poor. Finally, single crystal silicon was used to ensure accuracy and stability.
Direct installation pressure transmitter

Double flange differential pressure level transmitter

On October 19th, a dual flange liquid level transmitter with medium, hydrogen washing water, 316L+gold-plated diaphragm, capillary filled with fluorine oil, measuring range of 0-3m, DN50, PN16, diaphragm 316L+gold-plated, capillary length H=2.5m, L=3.5m, convenient for installing the transmitter body under the lower flange to extend its service life, radial installation, 1 set
Single flange liquid level transmitter, LT type, DN80,PN16, Tantalum film, range 0~120KPa, 4 units.
Double flange liquid level transmitter

Single flange liquid level transmitter