Product Technical Parameters | |||
1000 liter horizontal moving cold and hot shock test chamberpurpose |
The test chamber undergoes temperature shock between high and low temperatures by horizontally moving left and rightpart,The sample is placed in the testing area,The temperature in the high or low temperature zone during impact passes throughThe high-pressure cylinder is driven into the testing area for temperature shock, In order to achieve the goal of drastic temperature changes, the test product is static. This test chamber is suitable for assessing the ability of complete machine products, components, parts, materials, etc. to withstand rapid temperature changes. This temperature shock test is used to evaluate the test samples due to thermal expansion and contraction in the shortest possible timeChemical changes or physical damage caused, Be able to understand the impact of temperature changes on the test sample once or multiple times in a row. The main parameters that affect the temperature change test are the high and low temperature values within the temperature change range, the holding time of the test sample at high and low temperatures, and the number of cycles of the test. The thermal shock box is electronic,LED, Testing equipment for materials industries such as metal, plastic, rubber, coatings, paints, electronics, etc. |
||
1000 liter horizontal moving cold and hot shock test chamberfeature |
The experimental system has an advanced and reasonable structural design, standardized manufacturing process, and is a self-developed product with independent intellectual property rights. It has a beautiful and elegant appearance. The main functional components of this test chamber are all imported configurations (high gold content), with advanced and reliable technical principles, and optimal control of noise and energy saving - its performance can be comparable to similar foreign products. The matching and assembly of the three components are good, and the main functional components are all imported, which improves the safety and reliability of the product and ensures the long-term and high-frequency use requirements of users. The 4 devices have good operability, maintainability, good temperature stability and durability, good safety performance, do not pollute the environment and harm personal health. All wires inside the control cabinet are printed with serial numbers and numbers by dedicated equipment, and the wiring is clear and easy to understand. |
||
meet the standard |
1. GB/T2423.1-2001 Low temperature test methods; 2、GB/T2423.2-2001; 3. GB/T2423.22-1989 Temperature change test N; 4. GJB150.3-86; 5. GJB150.4-86; 6. GJB150.5-86; 7. GJB150.5-86 Temperature shock test; 8. GJB360.7-87 Temperature shock test; 9. GJB367.2-87 405 temperature shock test; 10. EIA 364-32 Thermal Shock (Temperature Cycling) |
||
Volume and size | |||
effective volume |
1000L |
||
Inner box dimensions |
W1000×H1000×D1000 mm |
||
outer box dimensions |
W1600×H2500×D2200 mm |
||
Performance indicators (ambient temperature)+5Measured under no-load conditions at ℃~30 ℃ | |||
temperature range |
-70℃~+180℃ |
||
Impact temperature range |
high temperature60℃~+150℃ low temperature-10℃~-40℃ |
||
Preheating temperature range |
+60℃ ~ +180℃ |
||
tallWenSlot liftWarm time |
RT(室Wen)~ +180℃≤30 minutes (room)WenIn+10~+30℃time). |
||
Pre cooling temperature range |
-10℃~-70℃ |
||
lowWenSlot descentWarm time |
RT(室Wen)~ -70℃≤70 minutes (room)WenIn+10-- +30℃time) |
||
WenDu Bomovedegree |
≤±0.5℃ |
||
WenDegree averageevendegree |
≤±2.0℃ |
||
Wind door conversion time |
≤ 5 seconds (cylinder opening conversion time) |
||
chargeReturn time of attack |
-40-- +150℃≤Within 5 minutes |
||
Temperature shock conditions |
high temperature~Low temperature, low temperature~high temperature, room temperature~high temperature~room temperature~low temperature, room temperature~low temperature~room temperature~high temperature |
||
power supply |
AC3¢5W 380V 50Hz (R, STN three-phase four wire with grounding wire) (voltage fluctuation ≤± 10%) |
||
Total power |
80KW |
||
Performance environment temperature requirements |
0~+30℃ |
||
cooling method |
The equipment adopts air cooling method |
||
Energy-saving design |
The refrigeration system can adjust the power according to the load size, using The VRF technology based on PID+PWM principle (electronic expansion valve servo control of refrigerant flow according to thermal energy conditions) and compressor energy regulation technology can achieve good energy-saving effect |
||
structural material | |||
Inner box material |
noStainless steelBoard(SUS#304) |
||
outer box material |
Cold rolled steel plate baked paint |
||
Insulation material |
100mm rigid polyurethane foam+glass fiber, flame resistant and fireproof, meeting environmental requirements |
||
door of the box |
A hinged insulation door panel made of the same material as the box body. Single door with explosion-proof handle. In order to prevent condensation or frosting at the edges of the door frame and door during low-temperature testing, electric defrosting devices are installed at the edges of the door frame and door |
||
Sample storage rack |
stainless steel SUS304 # adjustable spacing storage track 2 sets, grid storage rack 2The film. Load bearing capacity of each layer 20kg. The sample holder can be adjusted up and down as needed. |
||
seal |
The door of the test chamber is sealed with silicone rubber strip, which is resistant to high and low temperatures, aging and has good sealing performance |
||
High and low temperature cylinder conversion |
Adopt Taiwan, ChinaMade of professional pneumatic equipment components by "Yadeke" A. Divided into high temperature zone, low temperature zone, and experimental zone. The high and low temperature zones are used as energy reserves, while the experimental zone is the user use experimental zone. B. Valves can be opened and closed between the high and low temperature zones and the experimental zone. Automatically open the corresponding valve during impact. C. There is also an independent ventilation valve that operates to introduce ambient air during exhaust (room temperature recovery) |
||
caster |
The bottom of the machine adopts 4 sets of high-quality fixed universal movable wheels (easy to move) and flat water foot cups (adjust body balance) |
||
Manufacturing characteristics |
3D full parameter modeling, intelligent and efficient; Before manufacturing, PC virtual assembly will be carried out to ensure complete functionality and no design omissions; Motion simulation and stress analysis to ensure the rationality of the design. Channel modularization----Ensure manufacturing consistency and ensure stable batch performance. Joint processing---Japan imports high and low temperature resistant sealant and adds stainless steel pressure strip sealing treatment to ensure that the equipment does not deform and the structure does not leak air during long-term use. 3S Manufacturing Management Process - Manufacturing in the factory according to fixed scientific processes to ensure high efficiency and stable quality; Avoid making at the customer's site as the production process cannot be guaranteed, resulting in unstable performance. Welding and gluing process pictures |
||