2XZ type direct coupled rotary bladevacuum pumpScope of use
1. A pump is a basic device for obtaining vacuum, which can be used alone or as a pre pump and pre pump for various high vacuum systems.
2. The pump inlet shall operate continuously with open air for no more than three minutes.
3. Pumps are not suitable for extracting gases that are corrosive to metals, react chemically with pump oil, contain particulate dust, or contain explosive gases with high oxygen content.
4. Pumps shall not be used as compression pumps or delivery pumps.
5. The working environment of the pump: within the temperature range of 5 ℃ -40 ℃, with a relative temperature not exceeding 90% and an inlet pressure less than 1333Pa, it is allowed to operate continuously for a long time.
6. When installing the power supply, follow the wiring instructions on the motor label and ensure that the direction of motor rotation is consistent with the direction of the arrow on the support.
7. The diameter of the pipeline for continuous pumping of containers should not be less than the inlet diameter of the pump, and the pipeline should be short and have fewer bends, while paying attention to pipeline leakage.
8. Before starting each time, pay attention to checking the oil level, and it is advisable to fill the oil to a height of 4/5 of the diameter of the oil gauge glass when stopping the pump.
9. The pump oil used is clean SY1634-701 vacuum pump oil.
10. The pump can be started once under atmospheric or any vacuum level. If the XZ-1 single-stage pump has difficulty starting, the intake pipe plug cap can be removed to start and then put into operation.
Model meaning:
For example:
2XZ8
2- represents a two-stage pump
X - represents rotary vane vacuum pump
Z - represents the coupling between the pump and motor
8- represents the pumping rate per second
| model | pumping speed | Guanqi Town | Kaiqi Town | Speed (r/min) | voltage | Motor power (Kw) | Inlet diameter (mm) |
|---|---|---|---|---|---|---|---|
| Ultimate vacuum Pa | |||||||
| 2XZ-0.5 | 0.5 | 6.7×10 -2 | 1.33 | 1400 | 220 | 0.18 | φ19 |
| 2XZ-1 | 1 | 220 | 0.25 | φ19 | |||
| 2XZ-2 | 2 | 380/220 | 0.37 | φ30 | |||
| 2XZ-4 | 4 | 380/220 | 0.55 | φ30 | |||
| 2XZ-8 | 8 | 380 | 1.1 | φ30 | |||
2XZ series direct rotary bladevacuum pumpStructure diagram:

1 intake nozzle 2 filter screen 3 oil baffle 4 intake nozzle O-ring 5 rotary spring 6 rotary spring 7 rotor 8 pump body 9 oil tank 10 No.1 vacuum pump oil 11 exhaust valve plate