Welcome Customer !

Membership

Help

Yangzhou Wan'an Electric Heating Appliance Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Yangzhou Wan'an Electric Heating Appliance Co., Ltd

  • E-mail

    18118212378@qq.com

  • Phone

    18118212378

  • Address

    Chuangye Road, Industrial Concentration Zone, Liubao Town, Baoying County, Yangzhou City, Jiangsu Province

Contact Now

316 heater 380V/14KW/stainless steel 316 seamless DN50

NegotiableUpdate on 01/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
316 heater 380V/14KW/stainless steel 316 seamless DN50 sheathed electric heater SRY6-6 220V 6KW material 316 stainless steel sleeve indirect heater 220v9kw SUS316L component should be stored in a dry place. If the insulation resistance drops below 1 megohm due to long-term storage, it can be dried in an oven at around 200 ℃ for several hours (or the component can be low-voltage energized for several hours) to restore the insulation resistance.
Product Details

Sheath type electric heater SRY6-6 220V 6KWMaterial 316 stainless steel sleeve type indirect heater 220v9kw SUS316L

1316 heater 380V/14KW/stainless steel 316 seamless DN50SRY2/SRY4Application of Immersion Tube Electric Heater:

SRY2TheSRY3Type tubular electric heater is used for heating oil in open or closed oil tanks,SRY4The tubular electric heating component is used to heat flowing or circulating oil. This type of heater has a high surface load and is only suitable for use in oil with good heating effect.


Sheath type electric heater SRY6-6 220V 6KWMaterial 316 stainless steel sleeve type indirect heater 220v9kw SUS316L2、 Specifications and Technology316 heater 380V/14KW/stainless steel 316 seamless DN50parameter

1.Specifications and external dimensions: see table1And the picture1-2

SRYType tubular electric heater:

type number


electricity press
(ambush)

merit rate

(kilowatt)

Appearance and installation dimensions(millimeter)

heavy quantity

(kilogram)

A

BImmerse in oil for a long time

C

SRY2-220/1

220

1

307

230

'

1.45

SRY2-220/2

220

2

507

430

'

1.90

SRY2-220/3

220

3

707

630

'

2.35

SRY2-220/4

220

4

922

845

'

2.83

SRY3-220/1

220

1

625

375

570

0.77

SRY3-220/2

220

2

825

575

770

1.01

SRY3-220/3

220

3

925

675

870

1.13

SRY3-220/4

220

4

1125

875

1070

1.37

SRY4-220/5

220

5

697

620

'

2.45

SRY4-220/6

220

6

807

730

'

2.70

SRY4-220/8

220

8

1007

930

'

3.05


2.Allowable error of working voltage: not greater than its rated value1.1Twice. The casing should be effectively grounded.

3.Working environment: Relative humidity not exceeding95%No explosive, flammable, or corrosive gases.

4.Metal tube material:10Number steel.

5. Operating Temperature100℃。

6.SRY2TypeSRY4The work pressure of the type is less than0.6MPa.

7.Fuel tank opening: ≥ φ65.


3、 Usage, maintenance and precautions:

1.Dimensions in the external dimension diagram“B”It must be completely immersed in oil to avoid burning out the components. The heated oil should be non corrosive.

2. When melting solid oils such as asphalt and paraffin, the voltage should be reduced and then increased to the rated voltage after melting. To prevent heat concentration from reducing the lifespan of components.

3. When carbon deposits are found on the surface of the pipe, they must be removed completely before use to avoid reducing efficiency and even burning out components.

4.Components should be stored in a dry place. If the insulation resistance drops below due to long-term storage1At megaohms, it can be200Dry in an oven at around ℃ for several hours (or apply low voltage to the components for several hours) to restore insulation resistance.


4、 Selection of conventional tubular electric heaters:

SRY2/SRY4

Immersion oil heaterSRY2-1/SRY2-2Type threaded oil heaterSRY2-3(HRY14)Immersion type electric heaterSRY5(HRY10TheHRY11TheHRY12TheHRY13Top mounted angle ruler type oil heaterSRY6-12The3(HRY1)TheHRY2TheHRY3Type sheathed heaterSRY6-8Type sheathed heaterSRY6-9Type sheathed heater, SRY7Type straight holding heaterSRY8(HRY8TheHRY9Type finned heaterSRY9Type electric heaterSRY9-1Type thermal oil heaterSRYY6Type sheathed heaterSRQAir type heaterSRXYTheSRJNitric acid solution, alkaline solution heater, SRSType water heater, SRMMold heater, SRWType far-infrared heaterSRK3Type channel heaterLGRQ1Type biphenyl heaterLGRQ2Type biphenyl heaterLGRQ3Type biphenyl heaterLGRQ4Type biphenyl heaterGHKSeries hot air heatersSRY6FElectric heater for wind turbine gearboxGHY6FElectric heater for wind turbine gearboxBRExplosion proof heaterBRY2Type electric heaterBRY8Type electric heaterBRY15Type electric heater, pipeline electric heater(Online Heater Series)



Attachment:HRYType sheathed tubular electric heater:

model

HRY1

HRY2

HRY3

voltage
V

Surface power

w/cm2


Overall dimensionsmm

voltage
V

Surface power

w/cm2


Overall dimensionsmm

voltage
V

Surface power

w/cm2


Overall dimensionsmm

L

L1

L

L1

L

L1

1KW





220

1.4

440

360

380

1.4

440

360

2KW

380

1.0

1200

1120

220

2.0

590

510

380

2.0

590

510

3KW





220

2.1

790

710

380

2.1

790

710

4KW

380

1.8

1200

1120

220

2.2

1000

920

380

2.2

1000

920

5KW










2.3

1200

1120

6KW

380

2.8

1200

1120










SRY6List of Sheath type Electric Heating


Model

SRY6-1

voltage/power

Surface power of electric heating tube

cm2

Surface work of protective casing

cm2

Lmm

L1mm

380/2KW

0.8

1

1200

1120

380/4KW

1.6

1.8

1200

1120

380/6KW

2.4

2.8

1200

1120

380/8KW

2.8

3.5

1370

1300


Model

SRY6-2

voltage/power

Surface power of electric heating tube

cm2

Surface work of protective casing

cm2

Lmm

L1mm

220/1KW

1.25

1.4

440

360

22021KW

1.75

2

590

510

220/3KW

1.9

2.1

790

710

220/4KW

2

2.2

1000

920

220/5KW

2

2.3

1200

1120

220/6KW

2.4

2.8

1200

1120

220/8KW

2.8

2

1370

1300


Model

SRY6-3

voltage/power

Surface power of electric heating tube

cm2

Surface work of protective casing

cm2

Lmm

L1mm

380/1KW

1.25

1.4

440

360

380/2KW

1.75

2

590

510

380/3KW

1.9

2.1

790

710

380/4KW

2

2.2

1000

920

380/5KW

2

2.3

1200

1120



BRY2型 BGY2,BGY4,Precautions for Heater
1The components are allowed to operate under the following conditions:
AThe relative humidity of the air is not greater than95%No explosive or corrosive gases. (Excluding explosion-proof heaters)
BThe working voltage should not exceed the rated value1.1The shell should be effectively grounded.
CInsulation resistance≥1MΩdielectric strength:2KV/1min.
2Electric heating tubes should be properly positioned and fixed,The effective heating area must be completely immersed in liquid or metal solid, and empty burning is strictly prohibited. When scale or carbon deposits are found on the surface of the pipe body, they should be removed and reused in a timely manner to avoid affecting heat dissipation and shortening the service life.
3When heating molten metals or solid nitrate, alkali, asphalt, paraffin, etc., the operating voltage should be reduced first, and only after the medium melts can it be raised to the rated voltage.
4When heating air, the components should be arranged in a cross and even manner to provide good heat dissipation conditions, so that the air flowing through can be fully heated.
5When heating nitrate, safety measures should be considered to prevent explosion accidents.
6The wiring part should be placed outside the insulation layer to avoid contact with corrosive, explosive media, and moisture;The lead wire should be able to withstand the temperature and heating load of the wiring part for a long time, and excessive force should be avoided when tightening the wiring screws.
7The components should be stored in a dry place. If the insulation resistance is lower due to long-term storage1MΩAt that time, it is possible to200Dry in an oven at around ℃, or reduce the voltage and heat with electricity until the insulation resistance is restored.
8The magnesium oxide powder at the outlet of the electric heating tube should be protected from pollutants and moisture infiltration in the usage area to prevent leakage accidents.




Similar Product Recommend