The 6-channel electric cigarette life testing machine can meet the needs of all our electric cigarettes and cartridges for testing the number of suction ports, over suction protection, aging burn-in, temperature rise, suction, TPM testing, etc.
16-channel electricityziSmoke life testing machineProduct Introduction
This machine is used for testing electricityziCigarettes and e-liquids are aspirated using a cylinder piston system. By setting the corresponding smoking duration, smoking volume, and smoking frequency, electricity can be determinedziIs the cigarette qualified and suitable for both large and small power electricityziSmoke.
Secondly,6-channel electricityziSmoke life testing machineSpecifications
workstation |
6workstation |
Inhalation method |
Cylinder piston type (using6A cylinder |
Smoking volume |
150ML
(The supplier shall ensure that the set volume and actual consistency error do not exceed1ml)
|
Suction resistance control |
Automatic control of upper and lower limits of suction resistance, automatic alarm for exceeding the upper limit and falling below the lower limit |
duration |
1-9.9 Seconds(The supplier shall ensure that50-150mlAchieve the corresponding set parameter values under the single port volume |
Interval between each mouth |
1-999 Seconds |
Number of smoking ports |
1-999s |
power |
Stepper motor(6N/M)+PLC |
Cylinder push-pull mechanism |
ball screw |
Touch screen counter |
The number of times can be set, and it will automatically stop when the set number of times is reached |
special function |
Smoke free automatic stop operation and alarm prompt |
special function |
The following process can be set up at once: (automatic volume control)
For example, setting60mlEach bite lasts3Interval per second per bite5Seconds, total suction300Mouth, every50Oral interval10minute
|
Display and control mode |
touch screen+PLC+Self written program |
power supply |
1♪, ♪AC220V |
-
electricityziDetailed configuration of smoke inhalation testing machine:
- Framework: Adopting cold-rolled steel plate double-sided baking paint treatment, steel plate thickness ≥1.5mmThe suction tube adopts a fully transparent window for easy observation by the operator, and the thickness of the transparent window is ≥3mmThe front and back of the device are all equipped with movable doors+The buckle lock and movable door design are reasonable, making it easy for operators to quickly remove and clean components on a regular basis;
- Suction cylinder: It adopts a fully transparent cylinder with a scale, and the wall thickness of the cylinder is ≥4.0mmCylinder scale accuracy1mmThe suction cylinder is made of high wear-resistant and high-strength materials to ensure that it does not wear, scratch, deform, or crack. The fixed seat of the suction tube is easy to disassemble and assemble, and the sealing ring is designed reasonably. It is resistant to smoke and oil corrosion, and there will be no gas infiltration or leakage;
-
Suction piston: The suction piston has good sealing and small deformation, does not scratch the suction cylinder, and does not leak air. The piston rod adoptsFood grade stainless steelSUS304Not rusting or deforming;
-
Screw fixing seat and connecting components: using45#Steel chrome plating treatment orFood grade stainless steelSUS304Steel plate thickness ≥10mm;
- Control circuit: The control circuit is separated from the suction pipeline, and it is necessary to avoid the leakage of the pipeline during disassembly and assembly, which may affect the circuit and ensure safety;
- Pipeline: The suction cylinder pipeline is arranged at the top, the suction product pipeline is arranged in the middle, and the exhaust pipeline is arranged at the bottom. All pipelines have no horizontal layout to prevent oil accumulation in the pipelines;
- Exhaust gas collection device: The equipment is designed with an exhaust gas collection device that uses water cooling for collection;
- Program control system:
- Human machine interface: controlled by touch screen, touch screen size ≥7Inch;
-
Monitoring screen: capable of real-time collection of suction resistance pressure and voltage changes during the testing process, and outputting real-time curve graphs, data collection frequency30HZSwitchable display of real-time suction resistance, suction resistance value after stable flow rate, set capacity, suction time per port, interval time, and current suction cycle times;
- Number of smoking ports detection: The device has smoke mist detection function. When using real smoke cartridges for inhalation, if there is no smoke during inhalation, the device will alarm and stop, recording the actual number of smoking ports. If using simulated smoke bomb suction, this function can be blocked;
- The device can store test records: ≥50Group;
- Curve saving function: ThroughUSBTheLANInterface, availableUDrive to storage or connect to a computer to control, set parameters, print curve reports, etc. passWIFIThe module can also remotely download curve reports, etc;
-
Parameter setting: upper limit standard for suction resistance can be set/Lower limit standard, upper voltage limit standard/Lower limit standard, over limit equipment alarm shutdown;
-
Control mode: The equipment has 6 workstations that can be independently controlled(Reset, start, stop)The stability and accuracy of the test do not interfere with each other;
- Button: A power button switch and indicator light need to be configured. The power supply voltage for all personnel operating buttons is12V/24V;
- The device cannot be locked, remote control password cannot be set, and all program and electrical component interfaces must be open(Cannot set password);
- The equipment has a safety check function to ensure the safe operation of the machine and can automatically display the fault time, items, and troubleshooting measures. Can display historical data recording faults, such as statistical records of the causes and times of past faults;
- Good heat dissipation and safety protection measures are required inside the control cabinet. Each component and wiring terminal should be clearly labeled, and all wires should be covered with wire slots. All electrical components should be easy to maintain;
- The interface should be connected in a twisted pair configuration and insulated to prevent exposed copper;
-
The equipment casing is well grounded.
- Safety protection device:
- Upper and lower limit over limit protection;
- Short circuit and leakage protection;
- Motor overheating and overcurrent protection;
-
Fully sheathed terminal for the circuit.
- The device has no stability or accuracy degradation, and has a long service life10More than years old and in compliance with<3、 Detailed project requirements:第 2point>The relevant standard requirements;
- After the equipment testing product is completed, the conditions for starting the second test can be met immediately;
- The components inside the equipment are fixed and connected using screws+Nut fixation, avoid using self tapping screws for fixation;
- Equipment working time requirement: work no less than per month30Tian, working hours every day24H;
- Equipment failure rate requirement: The frequency of equipment failures should be ≤0.5time/Year;
- Energy efficiency meets national energy-saving standards, and equipment noise is below45dB.
- If the equipment requires the use of the following key components, relevant brands are required to be selected:
serial number |
Component Name |
brand |
Remarks |
1 |
Negative pressure sensor |
Ruitai Er(imported chips) |
|
2 |
ball screw |
Hiwin(Taiwan, China(THK) |
|
3 |
motor/controller |
Leadshine |
|
4 |
PLC |
Mitsubishi(Japan)Gu Mei |
|
5 |
touch screen |
Weilun Tong, Kunlun Tongtai, Gu Mei |
|
6 |
circuit breaker |
Schneider(Germany) |
|
7 |
button/indicator light |
Schneider(Germany) |
|
8 |
power switch |
Schneider(Germany) |
|
9 |
Relay, thermal relay |
Omron(Japan)Schneider(Germany) |
|
10 |
switching power supply |
Mean Well(Taiwan, China) |
|
11 |
trachea |
Airtac(Taiwan, China) |
|
12 |
tracheal connector |
Airtac(Taiwan, China) |
|
13 |
solenoid valve |
SMC(Japan) |
|