80G high-frequency radar level gaugeprinciple
The radar level antenna emits narrow microwave pulses, which are transmitted downwards through the antenna. After the microwave comes into contact with the surface of the measured medium, it is reflected back and received again by the antenna system. The signal is transmitted to the electronic circuit part and automatically converted into a level signal (because microwave propagation speed is extremely fast, the time it takes for electromagnetic waves to reach the target and reflect back to the receiver is almost instantaneous).
80G high-frequency radar level gaugefeature
The antenna size is small, making it easy to install; Non contact radar, no wear and tear, no pollution.
L Almost free from corrosion and foam; Almost unaffected by changes in water vapor, temperature, and pressure in the atmosphere.
The severe dust environment has little impact on the operation of high-frequency level meters.
Shorter wavelength, better reflection on tilted solid surfaces.
The small beam angle and concentrated energy enhance the echo capability while also helping to avoid interference.
The measurement blind spot is smaller, and it can also achieve good results for measuring small cans.
High signal-to-noise ratio enables better performance even in fluctuating conditions.
High frequency is the preferred choice for measuring solids and low dielectric constant media.
Power supply voltage
The (4-20) mA/HART (two-wire system) power supply and output current signal share a two core shielded cable. Please refer to the technical data for the specific range of power supply voltage. For intrinsic safety type, a safety barrier must be added between the power supply and the instrument.
(4-20) mA/HART (four wire system) power supply and current signal are separated, each using a two core shielded cable. Please refer to the technical data for the specific range of power supply voltage.
The RS485/Modbus power supply and Modbus signal line are separated and each uses a two core shielded cable. The specific power supply voltage range can be found in the technical data.
Safety guidance
Please comply with the requirements of the local electrical installation regulations!
Please comply with local regulations on personnel health and safety. All operations on the electrical components of instruments must be completed by professionals who have received formal training.
Please check the nameplate of the instrument to ensure that the product specifications meet your requirements. Please ensure that the power supply voltage is consistent with the requirements on the instrument nameplate.
Protection level
The protection level of this instrument is IP66/67. Please ensure the waterproof performance of the cable sealing head
instrument debugging
Three debugging methods:
① Display/button
② Upper computer debugging
③ HART handheld programmer
Display/button
Debug the instrument by using the four buttons on the display screen. The language of the debugging menu is optional. After debugging, it is usually only used for display, and the measured values can be read very clearly through the glass window.
Technical Specifications
Shell
Sealing silicone rubber between the outer shell and the outer shell cover
Polycarbonate shell window
Grounding terminal made of stainless steel
power supply voltage
Two wire standard type (16-26) V DC
Intrinsic safety type (21.6-26.4) V DC
Power consumption max 22.5mA/10W
Allow ripple
-<100Hz Uss < lV
- (100~100K) Hz Uss < l0mV
Cable parameters
Cable entry/plug 1 M20xl. 5 cable entry
1 blind block M20xl. 5
Terminal wire cross-sectional area 2.5mm ²
output parameters
Output signal (4-20) mA
Communication protocol HART
Resolution 1 6μA
The fault signal current output remains unchanged;
20. 5mA
22mA;
3.9mA
Integral time (0-50) s, adjustable
Blind spot antenna end
Large measurement distance of 80 meters
Microwave frequency 26GHz
Communication interface: HART communication protocol
Measurement interval is approximately 1 second (depending on parameter settings)
Adjustment time is approximately 1 second (depending on parameter settings)
Display resolution 1mm
Working storage and transportation temperature (-40~100) ℃
Process temperature (temperature of antenna part) (-40~250) ℃
Pressure Max. 4MPa
Seismic resistant mechanical vibration 10m/s ², (10~150) Hz