E-mail
admin@hssdtest.com
-
Phone
15966313580
-
Address
No. 4915 Jingshi West Road, Jinan City (88 meters west of Runhua Automobile Park)
Jinan Hengshi Shanda Instrument Co., Ltd
admin@hssdtest.com
15966313580
No. 4915 Jingshi West Road, Jinan City (88 meters west of Runhua Automobile Park)
The series of air spring lateral stiffness testing machines adopts an electric loading deceleration system to drive the precision ball screw pair to load after deceleration, achieving full digital adjustment of data acquisition and control process. Capable of conducting strength tests and analysis on precision springs such as tension springs, compression springs, disc springs, tower springs, leaf springs, card springs, leaf springs, composite springs, gas springs, mold springs, and irregular springs, including tension, pressure, displacement, and stiffness.
Air spring lateral stiffness testing machine
This series of products adopts an electric loading deceleration system to drive the precision ball screw pair to load after deceleration, achieving full digital adjustment of data acquisition and control process. Capable of conducting strength tests and analysis on precision springs such as tension springs, compression springs, disc springs, tower springs, leaf springs, card springs, leaf springs, composite springs, gas springs, mold springs, and irregular springs, including tension, pressure, displacement, and stiffness.
Air spring lateral stiffness testing machine|
Product Model |
TLW-10 |
TLW-20 |
TLW-30 |
TLW-50 |
TLW-100 |
TLW-200 |
TLW-300 |
|
|
Experimental force |
10kN |
20kN |
30kN |
50kN |
100kN |
200kN |
300kN |
|
|
Host structure type |
Four PillarsFloor standing model(Pull up and press down)/Press down and pull up) |
|||||||
|
Control method |
Computer fully automatic control |
|||||||
|
accuracy class |
1level |
|||||||
|
Test force measurement range |
2%~100% F · S (no distinction between internal and external) |
|||||||
|
Relative error of test force indication |
≤±1% |
|||||||
|
Relative error of displacement indication |
≤±1% |
|||||||
|
displacementdisplayresolution |
0.01mm |
|||||||
|
Deformation indication error |
≤±(50+0.15L)um |
|||||||
|
Speed adjustment range |
0.05-300mm/min |
0.05-200mm/min |
||||||
|
Relative speed error |
≤±1% |
|||||||
|
Effective stretching of space(mm) |
700 |
650 |
600 |
|||||
|
effectivecompressspace(mm) |
700 |
650 |
600 |
|||||
|
Effective experimental width(mm) |
400 |
450 |
550 |
|||||
|
Pressure plate diameter |
110mm |
|||||||
|
host power supply |
AC220V±10%,50Hz |
|||||||